Connect S | Connect L | Asset Monitoring and Tracking Gateway
7 | 13
Data subject not change without notice | Printed in Germany | June 06, 2016 | DRAFT
Bosch Connected Industry
5
Operations
Activation:
To activate a new Connect gateway hold an active NFC scanning device on top of the housing. The gateway will start
automatically and connect to the Bosch server for firmware download and configuration.
Device status:
Some battery status information can be red from the LED:
The Connect does not support a shutdown button. The device can only be turned off remotely.
Note: Connect Gateways must be off during flight transport!
LED
B
ATTERY
S
TATUS
flashing green,
1s interval
Device is in standby
flashing red,
1s interval
Device is operating: scan, GPS or upload running
flashing red,
15s interval
Battery too low, device is in battery protection mode, no operation possible
flashing green,
30s interval
Device is off, no operation. Battery ok. Device can be started by NFC activation.
flashing red,
30s interval
Device is off, no operation. Battery low, device can be started after re-charge.
no signal
Battery too low, device is off. Recharge device.
red 1s + green 1s
once
Start triggered. device is starting application
green
constant
With power supply connected. Battery charging. battery state > 90%
red
constant
With power supply connected. Battery charging. battery state < 90%