Bosch 1000P Manual Download Page 2

CT-13

page 2 of 2

rev 10/06

Bosch Water Heating

340 Mad River Park, Waitsfield, VT 05673

©

BBT

 NORTH AMERICA CORPORATION

Bosch Group

C. Cleaning burners

1. Use a soft wire brush across burner fins to loosen any

debris and then vacuum out.

2. Check to see that the 18 brass gas injectors in the

rear of the burner assembly are clean.  To access,
remove 8 Philips head screws to the left and right of
the two center brass Philips head screws at the rear
of the burner.  The burners should separate into two
halves exposing injectors.  Blow clean with com-
pressed air or carburetor cleaner and wipe dry with
cloth.  Do NOT poke injectors or attempt to clean with
drill bits, wires or other objects.  Clean rear venturi
passages with a pipe cleaner and soapy water.  Rinse
clean and let dry before reinstalling.  Follow instruc-
tions in reverse to reconnect burner halves.

D. Reinstalling burners

1. Reinstall burners into burner area.
2. Reinstall set screws on right side of gas valve and

tighten.

3. Reinstall right and left burner brackets with the four

screws.  The brass screws attach to frame.

E. Reinstalling pilot assembly and tube

Models 1000P, 1600P, 260PN, 425PN:
1. Reinsert thermocouple and snap into place.  Thermo-

couple tip should sit 1/4” above the burner bed.

2. Put spark electrode into place and attach with clip.

3. Slide upper end of pilot tube into bracket on burner

assembly and reinsert pin.

4. Slide base of pilot tube to the right into clip. Ensure

pilot air screen is installed between pilot tube and pi-
lot orifice.

Models 1600H, 425HN:
1. Slide pilot air screen  over pilot tube.
2. Slide pilot assembly into place.  Reinsert pilot shield

and secure with screws to the burner assembly.

F. Returning heater to service

Models 1000P, 1600P, 260PN, 425PN:
1. Turn on gas and light pilot. Test for possible gas leaks

where burners connect to the gas valve.

Models 1600H, 425HN:
1. Turn on gas and check for leaks where the burners con-

nect to gas valve by applying leak detecting solution as
you initiate water flow to activate the heater.  Allow
enough time to bleed all air in gas line. Bubbles are a
sign of a leak.

All models:
2. If there are bubbles at either connection immediately

shut off water and gas. Loosen the burner set screws
on the right side of gas valve.  Remove the burners and
inspect the o-ring. Replace if damaged. Reseat burners
and tighten set screws.  Check again for leaks.

3. Replace front cover when complete.

REMOVING AND CLEANING

BURNERS

FIGURE 5

Burners disassembled

Burner fins

Burner venturi passage

Gas injectors

Reviews: