Bosch Rexroth AG
83
9
Maintenance and repair
9.1
Cleaning and care
Maintenance and repair
8.5 Status bar
Tab.10: Status bar
LED
Meaning
Green steady light
Tightening case evaluation:
OK
Red static
Tightening case evaluation:
NOK
Yellow static
Ready for operation
Yellow flashing
The check interval defined
by the user has elapsed.
Red, yellow and
green are flashing
System error
Red, yellow, green
static
System boot
Yellow off
Not ready or in sequence
test
CAUTION
Direct contact with the detergent!
Direct skin or eye contact with the detergent
as well as swallowing or inhaling the detergent
may cause injuries.
Avoid direct physical contact with the
detergent.
Observe the instructions for use and first
aid in the "Technical safety sheet" as well as
in the "Safety data sheet" of the detergent
manufacturer.
NOTICE
Penetrating dirt or liquids!
Failures may occur. Safe function of the
product is no longer ensured.
Always provide for absolute cleanliness
when working with the product.
ES+CC-ES.book Seite 89 Montag, 14. Mai 2018 7:45 07
3608870H86/2020-01 |
ErgoSpin/CC-ErgoSpin
For cleaning ErgoSpin/CC-ErgoSpin hand-
held nutrunners and their components, use
the LOCTITE®
7063™
detergent, see the
manufacturer's information below.
Manufac-
turer:
Henkel AG & Co. KGaA
Henkelstr. 67
40191 Düsseldorf
Germany