5.1.2.2 Network configuration

Use DHCP: When enabled, IVAS will try to obtain an IP address from a DHCP server. If this fails, IVAS falls back to the static 

network configuration after 8 seconds. Enabled by default.

Current IP: Shows the current IP of the IVAS device and the static configuration. The text input allows modifying the static 

configuration.

Netmask: Netmask for static configuration

Figure 8: Configuration page

Gateway: Standard gateway IP for static configuration

MAC Address: MAC Address of the IVAS device

   Note:

 due to missing uniqueness of the MAC addresses in the early PoC IVAS devices you’ll face problems using 

more than one IVAS in the same network.

If two devices have the same MAC Address (which occurs more often than network administrators would like),  
neither computer can communicate properly. On an Ethernet LAN, this will cause a high number of collisions. 

Use auto streaming: When enabled, IVAS will always stream measurement data once connected to a network.  

Otherwise, streaming only starts with an active command connection. Disabled by default.

Target IP: In the case when auto streaming is enabled, IVAS will per default send data to this target IP address.  

This behavior can be overridden by opening a command connection.

Update network config: With this button, the configuration entered in the text input fields will be written to persistent 

memory. Will be available on subsequent power ons.

   Note: 

due to the early PoC IVAS device it is necessary to fill in every text box even if it should stay the same. 

Therefore please copy past the current settings from the left.

Extended configuration: In case there is an extended configuration present, it is written above the text input field.  

Summary of Contents for 0273600075

Page 1: ...Version 0 1 IVAS Sensor Device Ethernet Part No 0273600075 Operating Instructions ...

Page 2: ...This preliminary operating instructions present the status of the specifications It will be confirmed when validation has been completed with positive results Product part number 0273600075 ...

Page 3: ...3 Startup 10 4 2 4 Data streaming application 10 5 Ping messages autostreaming 11 5 1 Configuration firmware update 12 5 1 1 Login page 12 5 1 2 Configuration page 12 5 1 2 1 Status indication 12 5 1 2 2 Network configuration 13 5 1 3 Firmware update 14 5 1 4 Extended configuration 15 5 2 Hardware 15 5 2 1 General data 15 6 Installation handling and storage 15 6 1 Fixation 15 6 2 Connecting the mo...

Page 4: ...tand alone setup with three IVAS devices connected to a laptop through a PoE Switch 10 Figure 7 Login page 12 Figure 8 Configuration page 13 Figure 9 Firmware upload page 14 Table 1 Operating conditions 8 Table 2 Key features 8 Table 3 Default IVAS configuration 10 Table 4 Default port configuration 11 Table 5 Transmission of measurement data 11 Table 6 Packet structure 11 Table 7 Firmware version...

Page 5: ...ation based condition monitoring By analyzing the frequency spectrum created by machines and other moving parts e g in pumps motors linear drives or ventilation systems it is pos sible to assess the wear of bearings and other components This effectively allows the prevention of unplanned standstills For process monitoring this technique enables an integrated continuous quality control and gives th...

Page 6: ...essential requirements of 2014 30 EU EMC Directive for the intended use conditions environments and installation conditions described in the following Note Use of IVAS ETH for control of machinery under the aspect of functional safety is not authorized and voids the validity of the Declaration of Conformity DoC It is not allowed to integrate the IVAS ETH in controls of machinery e g for an emergen...

Page 7: ...anently installed in buildings Light industrial commercial residential as specified in EBN61000 6 1 and EN61000 6 3 for example residential buildings and areas such as houses apartments rooms commercial areas such are shops super markets wholesale markets office spaces for business and administration entertainment locations such as cinemas restaurants dancing clubs outdoor locations such as gas st...

Page 8: ...AS ETH as a Trojan horse for his malware Therefore never connect the IVAS ETH to the internet and move it back into the customer s network Note Use of IVAS ETH without the protective measures increases the risk of cyber attacks and can lead to interruption of machines falsified measurements unauthorized access to data in the customer s network and environment or other significant damage 2 2 3 Oper...

Page 9: ...sor module may at no time affect the safe use of the tagged asset In particular the follow ing places are not suitable for mounting the IVAS Sensor module Protective equipment Ventilation shaft and louvers Control elements Nameplates official license plates and lighting equipment Service and clutch areas as well as soft grip surfaces Areas in close proximity to flying sparks as well as areas with ...

Page 10: ...n Table 3 PARAMETER DEFAULT VALUE Use DHCP On Static IP Address 192 168 0 102 Netmask 255 255 255 0 Gateway 192 168 0 1 MAC Address 00 80 e1 00 00 01 Use Autostreaming Off Target IP 192 168 0 1 Table 3 Default IVAS configuration 4 2 3 Startup After being powered up IVAS enters the default data streaming application which transmits sensor measurements over the Ethernet network as configured When ac...

Page 11: ...e originating host on the respective sensor ports It is possible to modify the command port by sending a uint16 port number on the TCP connection All other ports are changed accordingly The new port configuration is only active until a reset Data transmission When activated sensor measurements are transmitted consecutively in the binary format specified in table 5 HIGH BANDWIDTH ACCELEROMETER HIGH...

Page 12: ...er unexpected network transactions the IVAS bootloader sends the login page as shown in figure 7 Username bosch Password sbss When the correct username and password are given the next page is the configuration page Figure 7 Login page 5 1 2 Configuration page The configuration page see figure 8 shows the current IVAS configuration and allows modifying it All configuration changes are stored persis...

Page 13: ...nistrators would like neither computer can communicate properly On an Ethernet LAN this will cause a high number of collisions Use auto streaming When enabled IVAS will always stream measurement data once connected to a network Otherwise streaming only starts with an active command connection Disabled by default Target IP In the case when auto streaming is enabled IVAS will per default send data t...

Page 14: ... IVAS Reset Complete appears the browser tab can be closed 5 1 3 Firmware update On the firmware upload page see figure 9 a file can be specified for upload After pressing the Upload button the upload process will start in the background This process as well as the file verification on the IVAS device CRC may take some time and should not be interrupted Once complete a status page is shown This pa...

Page 15: ...e average value might differ depending on software routine 6 Installation handling and storage 6 1 Fixation Fixation of the module is to be made using a M6 screw with 9 1 Nm Other fixation methods could damage the sensor module or influence the results of the measurement by preventing the vibration to be transferred correctly The fixation of the IVAS module should be made in a way that both marked...

Page 16: ... screw ISO 4762 M6 x 45 10 9 Screwing torque 9 1 Nm High frequency axis X axis Table 9 Assembly surface 6 2 Connecting the module 6 2 1 Electrical connection Connector M12 Pole X coded 8 poles M12 connector IEC 61076 2 109 According to IEEE 802 3 ...

Page 17: ...used to protect the connector during storage and or transport 7 Testing Testing is a key discipline to master product related risks The following test have been performed Conformity with EMC Directive Tests have been done under the requirements specified in harmonized standards listed in chapter 9 Conformity with PoE specifications In order to demonstrate conformity with PoE Power on the Ethernet ...

Page 18: ...ectromagnetic compatibility EMC Part 6 4 Generic standards Emission standard for industrial environments EN61000 6 4 2017 Electromagnetic compatibility EMC Part 6 4 Generic standards Emission standard for industrial environments EN12015 2014 Electromagnetic compatibility Product family standard for lifts escalators and moving walks EN50370 1 2005 Electromagnetic compatibility EMC Product family st...

Page 19: ...WISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE LwIP Swedish Institute of Computer Science Copyright c 2001 2004 Swedish Institute of Computer Science All rights reserved Redistribution and use in source and binary forms with or without modification are permitted provided that the following conditions are met 1 Redistributions of source cod...

Page 20: ...sclaimer in the documentation and or other materials provided with the distribution Neither the name of ARM nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE I...

Page 21: ...Ludwig Erhard Straße 2 72760 Reutlingen Germany support bosch connectivity com Postfach 1342 72703 Reutlingen Germany www bosch connectivity com Bosch Connected Devices and Solutions GmbH ...

Reviews: