Electrical Connections
5–1
1070 073 822-104 (02.06) GB
5
Electrical Connections
Please note that, with respect to all electrical connections, the terminal con-
nection plans and work instructions provided by the machine manufacturer
shall always be binding!
The system planner is also charged with providing and planning for the in-
tegration and implementation of required components, such as
Emergency-STOP circuits, mains switches, etc., in accordance with the cur-
rent state of the art and at the highest level of safety attainable.
CAUTION
Risk of damage to system components through by insertion or re-
moval of plug connectors on energized circuits!
Connections must be made only while the system is switched off.
Observe the following to prevent functional failures:
D
Provide for isolated 24 VDC and 0 V terminal bars inside the control cabi-
net. With regard to cable routing, maintain a minimum distance of 10 cm
(4 in.) from all power cables.
D
Design the overall system power circuits in a manner ensuring the simul-
taneous startup of operating terminals and other industrial components,
such as CNC and PLC.
Summary of Contents for IPC
Page 1: ...Antriebs und Steuerungstechnik IPC IPC300 Connectivity Manual Industrial PC 104 Edition ...
Page 12: ...Safety Instructions 1 8 1070 073 822 104 02 06 GB Notes ...
Page 18: ...IPC System Overview 2 6 1070 073 822 104 02 06 GB Notes ...
Page 70: ...Interfaces Ports Connectors 6 22 1070 073 822 104 02 06 GB Notes ...
Page 72: ...LED Display 7 2 1070 073 822 104 02 06 GB Notes ...
Page 75: ...Maintenance and Replacement 8 3 1070 073 822 104 02 06 GB IPC300 Fuse ...
Page 88: ...Maintenance and Replacement 8 16 1070 073 822 104 02 06 GB Notes ...