EN
BEFORE USING
Carry out a function test and visual
inspection every time before use.
• The personal protective equipment (PPE) may
no longer be used even in the case of very
minor faults.
• In case of damage or malfunctions, the device
must be withdrawn and returned to the
manufacturer for inspection. Faulty PPE may
only be tested and serviced in a workshop
authorised by BORNACK.
VISUAL INSPECTION
• Check that the device is complete. Are all
parts in place?
• Check for damage.
• Are all seams undamaged?
• Do textile components show signs of visible
damage or can damage be felt?
• Fall indicator undamaged?
• Last expert inspection is not longer than
1 year ago.
• Identification is legible.
FUNCTION TEST
• Is the karabiner fastener and lock fully
functional?
• HSG blocks when jerked out.
• Band winds up automatically. No slack rope is
created.