Technical Data
Μodels
BAT5002 (24 l) & BAT 5012 (50 l)
Rated Power Input
2hp
Rated Voltage - Frequency
220 V (~) - 50 Hz
Flow rate
188 l/min
Installation
LOCATION:
It is extremely important to use the compressor in a clean, well ventilated area where the surrounding air temperature will not be more than 100°F.
A minimum clearance of 18 inches between the compressor and a wall is required because objects could obstruct air flow.
CAUTION Do not locate the compressor air inlet near steam, paint spray, sandblast areas or any other source of contamination. This debris will damage the
motor.
GROUNDING INSTRUCTIONS
1. This product is for use on a nominal 220 volt circuit and has a grounding plug that looks like the plug illustrated in Fig. 1. Make
sure the product is connected to an outlet having the same configuration as the plug. This product must be grounded. In the event of an electrical short circuit,
grounding reduces risk of electrical shock by providing an escape wire for electric current. This product is equipped with a cord having a grounding wire with
an appropriate grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
DANGER
Improper use of grounding plug can result in a possible risk of El
DANGER
Do not use a grounding adapter with this product!
2. If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external
surface that is green (with or without yellow stripes) is the grounding wire. Never connect green (or green and yellow) wire to a live terminal. 3. Check with a
qualified electrician or serviceman if grounding instructions are not completely understood, or if in doubt as to whether product is properly grounded. Do not
modify plug provided; if it will not fit outlet, have proper outlet installed by a qualified electrician. Overheating, short cirucuting and fire damage will result
from inadequate wiring, etc.
Operation
Definition of Terms ASME Safety Valve
- This valve automatically releases air if the tank pressure exceeds the preset maximum.
Handle
- Designed to move
the compressor.
Drain Valve
- This valve is located on the bottom of the tank. Use this valve to drain moisture from the tank daily to reduce the risk of cor
-
rosion. Reduce tank pressure below 10 psi, then drain moisture from tank daily to avoid tank corrosion. Drain moisture from tank by opening the drain valve
located underneath the tank.
LUBRICATION
This is an oilless product and
DOES NOT
require lubrication to operate.
BEFORE FIRST STARTUP BREAK-IN PROCEDURE
(Complete this procedure before using compressor for the first time. Once completed, it is not necessary to
repeat.) 1. Do not attach a hose or any other fitting to the compressor. 2. Turn on/off switch to OFF position. 3. Plug in power cord. 4. Turn on/off switch to
ON position. Allow compressor to run for 5 minutes. 5. Turn on/off switch to OFF position. 6. Unplug power cord.
BEFORE EACH STARTUP OPERATING PROCEDURE
1. Connect air hose to open port located below pressure gauge. 2. Attach the necessary fitting or tool to
open end of air hose. 3. Turn on/off switch to OFF position. 4. Plug in power cord. 5a. If using inflation needles/nozzles: Attach air hose with inflation fitting
to the object you are going to inflate. While holding inflation fitting firmly in place, turn on/off switch to ON position. Allow compressor to inflate the object.
Turn off compressor and remove inflation fitting. 5b. If using tire chuck or tool: Once chuck or tool is attached to air hose, turn on/off switch to ON position
and allow compressor to run until it automatically shuts off. When using tire chuck to inflate tires, observe gauge reading on compressor and periodically
check tire pressure with a separate tire gauge to prevent overinflation.
ON/OFF cycling of compressor
In the ON position, the compressor pumps air into the tank. When a shut-off (preset "cut-out") pressure is reached, the com
-
pressor automatically shuts off. If the compressor is left in the ON position and air is depleted from the tank by use of a tire chuck, tool, etc., the compressor
will restart automatically at its preset "cut-in" pressure. When a tool is being used continuously, the compressor will cycle on and off automatically. In the OFF
position, the pressure switch cannot function and the compressor will not operate. Make sure switch is in OFF position when connecting or disconnecting
power cord from electrical outlet.
ASME SAFETY VALVE
WARNINGI the safety valve! Do not remove or attempt to adjust.
Handle
ON/OFF
Switch
Drain valve
Pressure Gauge
Safety Valve
Figure 2 - Unit Identification
Figure 1 - Grounding Method
Grounded Outlet
Grounded Pin