Technical Data 

Μodels

BAT5002 (24 l) & BAT 5012 (50 l)

Rated Power Input

2hp

Rated Voltage - Frequency

220 V (~) - 50 Hz

Flow rate

188 l/min

Installation 

LOCATION: 

 It is extremely important to use the compressor in a clean, well ventilated area where the surrounding air temperature will not be more than 100°F. 

A minimum clearance of 18 inches between the compressor and a wall is required because objects could obstruct air flow.  

CAUTION Do not locate the compressor air inlet near steam, paint spray, sandblast areas or any other source of contamination. This debris will damage the 

motor.

GROUNDING INSTRUCTIONS 

1. This product is for use on a nominal 220 volt circuit and has a grounding plug that looks like the plug illustrated in Fig. 1. Make 

sure the product is connected to an outlet having the same configuration as the plug. This product must be grounded. In the event of an electrical short circuit, 

grounding reduces risk of electrical shock by providing an escape wire for electric current. This product is equipped with a cord having a grounding wire with 

an appropriate grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

DANGER

 Improper use of grounding plug can result in a possible risk of El

DANGER 

 Do not use a  grounding adapter with this product! 

2. If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external 

surface that is green (with or without yellow stripes) is the grounding wire. Never connect green (or green and yellow) wire to a live terminal. 3. Check with a 

qualified electrician or serviceman if grounding instructions are not completely understood, or if in doubt as to whether product is properly grounded. Do not 

modify plug provided; if it will not fit outlet, have proper outlet installed by a qualified electrician.  Overheating, short cirucuting and fire damage will result 

from inadequate wiring, etc. 

Operation 

Definition of Terms ASME Safety Valve

 - This valve automatically releases air if the tank pressure exceeds the preset maximum. 

Handle

 - Designed to move 

the compressor. 

Drain Valve

 - This valve is located on the bottom of the tank. Use this valve to drain moisture from the tank daily to reduce the risk of cor

-

rosion. Reduce tank pressure below 10 psi, then drain moisture from tank daily to avoid tank corrosion. Drain moisture from tank by opening the drain valve 

located underneath the tank. 

LUBRICATION

 This is an oilless product and 

DOES NOT

 require lubrication to operate. 

BEFORE FIRST STARTUP BREAK-IN PROCEDURE

 (Complete this procedure before using compressor for the first time. Once completed, it is not necessary to 

repeat.) 1. Do not attach a hose or any other fitting to the compressor. 2. Turn on/off switch to OFF position. 3. Plug in power cord. 4. Turn on/off switch to 

ON position. Allow compressor to run for 5 minutes. 5. Turn on/off switch to OFF position. 6. Unplug power cord. 

BEFORE EACH STARTUP OPERATING PROCEDURE 

1. Connect air hose to open port located below pressure gauge. 2. Attach the necessary fitting or tool to 

open end of air hose. 3. Turn on/off switch to OFF position. 4. Plug in power cord. 5a. If using inflation needles/nozzles: Attach air hose with inflation fitting 

to the object you are going to inflate. While holding inflation fitting firmly in place, turn on/off switch to ON position. Allow compressor to inflate the object. 

Turn off compressor and remove inflation fitting. 5b. If using tire chuck or tool: Once chuck or tool is attached to air hose, turn on/off switch to ON position 

and allow compressor to run until it automatically shuts off. When using tire chuck to inflate tires, observe gauge reading on compressor and periodically 

check tire pressure with a separate tire gauge to prevent overinflation. 

ON/OFF cycling of compressor 

 In the ON position, the compressor pumps air into the tank. When a shut-off (preset "cut-out") pressure is reached, the com

-

pressor automatically shuts off. If the compressor is left in the ON position and air is depleted from the tank by use of a tire chuck, tool, etc., the compressor 

will restart automatically at its preset "cut-in" pressure. When a tool is being used continuously, the compressor will cycle on and off automatically. In the OFF 

position, the pressure switch cannot function and the compressor will not operate. Make sure switch is in OFF position when connecting or disconnecting 

power cord from electrical outlet. 

ASME SAFETY VALVE 

WARNINGI the safety valve!  Do not remove or attempt to adjust. 

Handle

ON/OFF 

Switch

Drain valve

Pressure Gauge

Safety Valve

Figure 2 - Unit Identification 

Figure 1 - Grounding Method

Grounded Outlet

Grounded Pin 

Summary of Contents for 042389

Page 1: ...WWW BORMANNTOOLS COM E N E L 2 B A T 5002 B A T 5012 042389 042396...

Page 2: ...ment is not simultaneously used existing warranties shall be voided 1 Read all instructions included with this product carefully Be thoroughly familiar with the controls and the proper use of the equi...

Page 3: ...his valve to drain moisture from the tank daily to reduce the risk of cor rosion Reduce tank pressure below 10 psi then drain moisture from tank daily to avoid tank corrosion Drain moisture from tank...

Page 4: ...cake and clog the gun rendering it ineffective A filter in the air line MP3105 located as near to the gun as possible will help eliminate this moisture 1 Turn compressor off and release pressure from...

Page 5: ...ring worn 1 Decrease usage or purchase unit with higher air delivery SCFM 2 Check all connections with soap and water solution If a leak is detected tighten Or remove fitting and apply pipe tape to th...

Page 6: ...ORMANNTOOLS COM E L General safety instructions D Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 CSA Canadian Standard Association 1 2 OSHA 3 4 5 6 7 8 9 10 11 12 1...

Page 7: ...WWW BORMANNTOOLS COM E L 16 17 18 19 M BAT5002 24 l BAT 5012 50 l 2hp 220 V 50 Hz 188 l min 100 F 37 77 38o C 18 45 72 cm 1 220 volt 1 2 3 ASME 10 psi 1 2 OFF 3 4 ON 5 5 OFF 6 1 2 3 OFF 4 ON OFF B 2...

Page 8: ...8 WWW BORMANNTOOLS COM E L 5a ON 5b FF ON K ON OFF ON cut out ON cut in pressure OFF OFF ASME 1 2 3 40 50 PSI MP3105 1 ASME ANSI 287 1 2 3 100 F 37 77 38 C 1 2 3...

Page 9: ...ANNTOOLS COM E L 1 FF OFF 2 3 Shut off Pressure 4 5 1 2 E 3 4 30 reset 100 o F 37 77 37 8o C 5 1 2 1 100 o F 37 77 37 8o C 2 1 2 3 1 2 3 shut off 1 2 3 1 2 3 1 2 3 4 1 SCFM 2 3 4 1 2 1 2 1 2 1 2 1 2 1...

Page 10: ......

Reviews: