BorMann 037279 Operating Instructions Manual Download Page 8

EN

WWW.BORMANNTOOLS.COM

8

Step

Digital display

LED indicator

Charging state

FLOATING

CHARGING

BATT-12/24

CHARGING LED lit

Maintaining the battery voltage to 

continuously absorb current.

ANALYSIS-3

ANALYSING-3

BATT-12/24

CHARGING LED lit

Analysing if the battery can store 

electric charge.

MAINTAINING

MAINTAINING

BATT-12/24

CHARGED/MAINTAINING LED lit

The battery is charged and the 

charger is maintaining the battery.

Protecting the environment

Should you find one day that your appliance needs replacement, or if it is of no further use to you, think of the protection of the environment. 

The retailers will accept used tools and ensure that they are disposed of in an environmentally safe way. 

Separate collection of used products and packaging allows materials to be recycled and used again. Re-use of recycled materials helps prevent 

environmental pollution and reduces the demand for raw materials. 

Local regulations may provide for separate collection of electrical products from the household, at municipal waste sites or by the retailer when 

you purchase a new product. 

Lead acid batteries can be recharged many times. At the end of their useful life, discard batteries with due care for our environment: Do not dispose of the 

battery in fire, as this may result in an explosion. 

Lead acid (Pb) batteries are recyclable. They must not be disposed of with household waste. 

The battery must be removed and disposed of in accordance with local regulations. Do not short-circuit the battery terminals. 

Be aware that the battery is heavy. 

If possible, operate the appliance to run the battery down completely. Place the battery in a suitable packaging to ensure that the terminals cannot be short-cir-

cuited. 

Take the battery to your service agent or a local recycling station. Collected batteries will be recycled or disposed of properly.

Summary of Contents for 037279

Page 1: ...Art Nr WWW BORMANNTOOLS COM en el BBC7020 BBC7550 v2 1 037279 037286...

Page 2: ...to supply power to an extra low voltage electrical system or to charge dry cell batteries Charging dry cell batteries may burst and cause injury to persons and property 11 NEVER charge a frozen damage...

Page 3: ...Plastic Handle 21 Plastic panel 22 FUSE 23 Metal shell 24 AC PLUG 25 Wheel 26 Negative Battery clamp 27 Positive Battery clamp 28 24V quick connector 29 12V quick connector 1 This product is designed...

Page 4: ...ations Our warranty will be voided if the machine is used in commercial trade or industrial businesses or for equivalent purposes To ensure the safety and reliability of the product and the warranty v...

Page 5: ...rk LITHIUM LED lit Charging 12V lithium ion batteries only including 4 cell LiFePO4 24V STD LED lit STANDARD Charged Voltage is 28 8V When charging pressing this button does NOT work GEL LED lit GEL C...

Page 6: ...ts The positive battery terminal is typically marked by these letters or symbol POS P The negative battery terminal is typically marked by these letters or symbol NEG N 2 Do not make any connections t...

Page 7: ...maximum output as required by the starting system for up to 5 seconds 3 Cool Down After cranking the charger enters a mandatory 240 seconds cool down state Pressing any button does NOT work The digit...

Page 8: ...aterials helps prevent environmental pollution and reduces the demand for raw materials Local regulations may provide for separate collection of electrical products from the household at municipal was...

Page 9: ...WWW BORMANNTOOLS COM 10 EL 1 2 3 4 5 6 7 8 9 10 11 12 15 1 2 3 4 DC AC 5 6 7 8 9 10 230volt...

Page 10: ...4 LED 5 LED 6 LED 7 LED STD 8 LED GEL 9 LED AGM 10 LED 12V LITHIUM 11 12 LED 5A 15A 13 LED BOOST 25A LED 28 24V 14 LED 29 12V 15 16 LED 17 LED 18 19 LED 20 21 22 23 24 AC 25 26 27 28 24V 29 12V 25 50...

Page 11: ...12 24VDC 20 30 50 70A 200A 250A 1V 500A 600A 1V 300AH 12 24V WET MF CA EFB GEL AGM 750AH 12 24V WET MF CA EFB GEL AGM 3V 3V STD GEL AGM 12V 24V 10 IP20 STD GEL AGM 12V 24V 10 IP20 Service LED 0 5 LED...

Page 12: ...hium ion 4 cell LiFePO4 24V LED STD STANDARD 28 8V LED GEL GEL 29V LED AGM AGM 29 6v LED E01 LED Change red and black clamps or ring terminals to the correct battery posts E02 LED 0 E03 LED NORMAL 10A...

Page 13: ...LED E04 LED 1Volt 1 2 3 4 BATT MISMATCH LED 12V 24V 1 POS P NEG N 2 3 NEG POS 4 5 6 7 1 2 LED 3 LED ENGINE START OFF NORMAL 10A CHARGING NORMAL 30A CHARGING BOOST 50A CHARGING 12V REPAIR REPAIR ON LE...

Page 14: ...READY 2 5 3 240 240 0 4 START READY TEST FUNCTION TEST 1 2 AC AC 3 0 100 Lo Hi LED ANALYSIS 1 ANALYSING 1 BATT 12 24 LED DESULPHATION CHARGING BATT 12 24 LED CHARGING BULK CHARGING BATT 12 24 LED CHA...

Page 15: ...WWW BORMANNTOOLS COM 16 EL LED FLOATING CHARGING BATT 12 24 LED CHARGING ANALYSIS 3 ANALYSING 3 BATT 12 24 LED CHARGING MAINTAINING MAINTAINING BATT 12 24 LED Pb V A...

Page 16: ......