46 |
u1 Undercounter Systems
Install & Operation Guide
GB
Electrical Test Measurement
Values Guide
BK Series
Compressor Resistance
Primary
13
Ω
Secondary
44
Ω
Total
57
Ω
Compressor Input Voltage 230V
230V
Compressor Relay
Resistance
PTC
3 – 6
N/A
3 – 5
N/A
5 – 6
23.8
Ω
Compressor Relay Resistance
Klickson
1.6
Ω
Solenoid Coil
Resistance
Cold Dispense
(
≥
0906)
84
Ω
Ambient Dispense
(
≥
0906)
84
Ω
Sparkling Dispense
(
≥
0906)
84
Ω
Tank Fill
(
≥
0906)
84
Ω
Pump Feed
(
≥
0906)
84
Ω
Cold Dispense
(All)
N/A
Hot Dispense
(All)
84
Ω
Solenoid Valve Input Voltage
24VDC
Cooling
Current/Power
Normal
At 230V
N/A
Reduced
At 230V
N/A
Ineffective
At 230V
N/A
Heater Resistance
Main Element
(400W/1.74A)
N/A
(535W/2.33A)
N/A
(825W/3.58A)
N/A
Standby Element
(35W/0.15A)
N/A
(50W/0.22A)
N/A
Heater Band Input Voltage
230V