General Safety

General Safety

-  Always place the dispenser in its vertical position,  

on a surface which can capably support its weight.

-  During use this machine must remain in 

its upright position.

-  Adequate ventilation must be allowed for - we  

recommend using the supplied ventilation ducting kit.

-  Keep the machine away from sunlight, heat and moisture.

-  The environment where this machine is installed must be  

free of dust and corrosive/explosive gases.

Basic Troubleshooting

Problem/Report

Possible Cause

Suggested Action

No Water Dispensing

Water Pressure Regulator

Contact your distributor

No Sparkling Water -  

If applicable

No CO2 pressure

Check CO2 bottle, regulator and non- return 

valve. Supply pressure should be 58 psi (3.5-

4bar), replace as necessary

Carbonator Tank Not Filling

Contact your distributor

Poor Quality Carbonation -  

If applicable

Air in Carbonator Tank

Isolate the power supply and operate the 

sparkling water tap until gas is expelled. Allow 

gas to expel for 5 seconds. Switch on power 

supply and allow the tank to refill

Residue in Carbonator Tank

After prolonged use, a surface film can develop 

within the carbonator tank. Refer to cleaning 

and sanitising instructions

Carbonator Tank is Overfilled

If pump runs continuously, contact your 

distributor

Warm Drinks

Insufficient cooling air flow through the fridge

Check that the ventilation kit has been installed 

correctly.

Compressor not running

Contact your distributor

PCB not operating

Fridge failure

Summary of Contents for ProCore C2

Page 1: ...tents Component Feature Overview Operation Functions Controls General Safety CO2 Bottle Installation Chilled Ambient Sparkling NOTE This booklet to be left with appliance following installation User Guide C2 C3 Tap systems ...

Page 2: ...et Please Note Mains Installation Kit Filters are supplied as extra items according to individual ordering requirement Ambient water pipe always longest c2 c3 Tap Major Components Ambient Water Tap Sparkling Water Tap Chilled Water Tap Dispense Lever Main Body Gasket Threaded Stem Backnut Chilled Water Pipe Sparkling Water Pipe Ambient Water Pipe ...

Page 3: ...r Cord Set 1 no Co2 Regulator with Gauge Connection tube 1 no Ventilation Ducting Kit ProCore Undercounter Major Components Water Inlet CO2 Inlet Ambient Dispense Unit Carry Handle Side Panel Top Cover Sparkling Dispense Chilled Dispense On Off Switch Power Connection ...

Page 4: ...Front Panel Easy fit Ventilation Base Ventilation Chimney ...

Page 5: ...e or decrease flow rate Lever in the upright position is fully closed Ambient Water Tap Sparkling Water Tap Chilled Water Tap Flow Restrictor Lever OPEN OPEN CLOSED Sparkling versions only Dispensing from unit Pull and hold the dispense lever towards you and release to finish dispense ...

Page 6: ...ure Check CO2 bottle regulator and non return valve Supply pressure should be 58 psi 3 5 4bar replace as necessary Carbonator Tank Not Filling Contact your distributor Poor Quality Carbonation If applicable Air in Carbonator Tank Isolate the power supply and operate the sparkling water tap until gas is expelled Allow gas to expel for 5 seconds Switch on power supply and allow the tank to refill Re...

Page 7: ...stand for 8 12 minutes for the initial chilling process to complete It is necessary to prime the sparkling system pull the sparkling handle for a few seconds until CO2 is coming through Check and adjust the CO2 pressure accordingly Connect the assembled CO2 bottle and regulator to the CO2 inlet using a pipe We recommend between 3 5 4 bar 58 PSI max Do not exceed 4 bar pressure 58 PSI CO2 Bottle In...

Page 8: ...borgandoverstrom com manual c2 c3 Customer services aftersales borgandoverstrom com call 44 1362 695 006 Copyright Borg Overström This guide is printed by Borg Overström and shall not be reproduced or copied in anyway Ref 701716 Version V 18012022 ...

Reviews: