![Borg & Overstrom f4 Install & Operation Manual Download Page 5](http://html.mh-extra.com/html/borg-and-overstrom/f4/f4_install-and-operation-manual_2788483005.webp)
GB
6. The thermostat is factory preset and should
not need further adjustment.
7. Refit the Front panel.
8. Allow 1hr for the water to cool before
the dispense water reaches its
operational temperature.
10 c
4 c
Operation & Maintenance
1. Frequently clean the fountain using warm
soapy water. Avoid all abrasive and corrosive
cleaning materials.
2. Do not pour any dregs or other waste into
the waste water fitting to avoid blocking the
waste system.
3. If required, the power can be switched off
when not using the fountain for an extended
period of time (e.g. more than 3 days) to
conserve energy. However we recommend
that the fountain is cleaned and at least 10
litres of water is flushed through upon switching
on again for re-use. It may also be necessary
to change the filter after an extended period of
dis-use.
4. Keep the area surrounding the fountain
clean and dry.
In the event of any leakages, switch off the
water and power and call your service
engineer.
Performance Data
Function
Cooling
Voltage
Frequency
Max Cooling Power
Cooling
Capacity
Refrigerant
Type
Refrigerant
Charge
220 - 240V
50Hz
120W
40 Ltrs/Hour
R134a
110g