Installation Requirements
• Identify a suitable location for the ProCore unit. It should be positioned within 1.0m of the faucet, and within 2.0m
of suitable services connections. Allow enough space to fit the ventilation ducting system.
• The ProCore unit must be installed in accordance with the relevant requirements of:
• The appropriate building regulations by application of either The Building Regulations (England and
Wales), The Building Regulations (Scotland) or The Building Regulations (Northern Ireland). In territories
other than those listed the local regulations in force must be complied with.
• The Water Supply (Water Fittings) Regulations (England, Wales and Northern Ireland) or The Water
Byelaws in Scotland.
• The unit must not be installed where it is liable to freeze. If the unit is thought to be frozen it must not be switched
on. It should be allowed to thaw and must then be thoroughly inspected to ensure it is undamaged.
• Water: Mains potable water – internally regulated to 0.3MPa (3 bar)
• Minimum to maximum ambient room operating temperature: 5°C - 35°C
• CO2: Food Grade CO2 to be supplied
• Min mains pressure 0.05MPa (0.5 bar)
• Electricity: 5A supply – Earth Leakage Protected
• Waste Drain Connection
CO2 Bottle Installation - Sparkling Versions Only
2
1
3
OFF
58 PSI
4
Unpack CO2 Regulator and fit
elbow fitting to spigot outlet.
Attach the regulator to the
CO2 bottle, ensuring the small
pressure relief vent in the stem
is facing away from you or
anyone else. Ensure the regulator
is closed. Hand tighten securely.
Connect the assembled CO2
bottle and regulator to the CO2
inlet using a ¼” pipe.
Stand the cylinder in a suitable
place. We recommend between
3.5 - 4 bar (58 PSI) (max). Do
not exceed 4 bar pressure.