6 The conditions listed below are not classified into errors. 

Table 10 

Conditions

Causes

The unit does not run

When restart the unit soon after it is 

stopped.

The overload protection switch of the unit let the 

startup delayed for three minutes.

As soon as power is on.

The  unit will  stand  by  for  approximate  one 

minute.

The unit blows out mist

When the cooling operation starts.

The hi-humidity air indoor is cooled quickly.

The unit generates noise

The  unit  “ clatters” as  soon  as  it 

starts running.

It  is  the sound  generated  during  the  initialization 

of the electronic expansion valve.

The  unit  “ swishes” during  the 

cooling operation.

It is the sound when the refrigerant gas runs inside 

the unit.

The  unit  “ swishes” when  it  is 

started or stopped.

It  is  the  sound  when  the  refrigerant  gas  stops 

running.

The unit  “ swishes” when it is in 

and after the running.

It  is  the  sound  when  the  draining  system  is 

operating.

The unit  “ squeaks” when it is in 

and after the running.

It  is  the sound  of frication  generated  by  the skin 

plate  etc  which  swells  due  to  the  temperature 

change.

The unit blows out dust.

When the unit restarts after it is not 

used for a long time.

The dust inside the unit is blown out again.

The unit emits odors.

When the unit is running.

The odors absorbed in are blown out again.

NOTICE! 

If problem can not be solved after checking the above items, please contact service center and show 

phenomena and models. 

Following circumstance are not malfunction 

Table 11 

Malfunction

Reason

Unit doesn’t run

When unit is started 

immediately after it is just 

turned off

Overload protection switch makes it run after 3 minutes 

delay

When power is turned on

Standby operating for about 1 minute

Mist comes from the 

unit

Under cooling

Indoor high humidity air is cooled rapidly

Noise is emitted

Slight cracking sound is heard 

when just turned on

It is noise when electronic expansion valve initialization

There is consecutive sound 

when cooling

That's sound for gas refrigerant flowing in unit

There is sound when unit starts 

or stops

That's sound for gas refrigerant stops to flow

There is slight and consecutive 

sound when unit is running or 

after running

That's sound for operation of drainage system

Cracking sound is heard when 

unit is operating and after 

operating

That’s sound caused by expansion of panel and other 

parts due to temperature change

The unit blows out 

duct

When unit runs after no 

operation for a long period

Dust in indoor unit is blew out

The unit emits odor

Operating

The room odor absorbed by the unit is blew out again

Indoor unit still runs 

after switch off

After every indoor unit receive 

"stop" signal, fan will keep 

Indoor fan motor will keep running 20-70s so as to take 

good use of excess cooling and heating and prepare for 

Summary of Contents for Brisa MBRS42HPJ1OA

Page 1: ...For proper operation please read and keep this manual for future reference If you have lost the Owner s Manual please contact the local agent or visit www borealintl com or send an email to borealsale...

Page 2: ...e normal condition by harmonizing their running modes the cooling mode is compatible with the dehumidifying mode and the fan mode can go with any other mode If the supply power fails when the unit is...

Page 3: ...n of such waste separately for special treatment is necessary Exception Clauses Manufacturerwillbearnoresponsibilitieswhenpersonalinjuryorpropertylossiscausedbythefollowingreasons 1 Damagetheproductdu...

Page 4: ...3 3 Piping Connection 7 4 Installation Instruction 8 4 1 Outline and dimension of the outdoor unit 8 4 2 Installation of the Connection Pipe 9 4 3 Air Purging and Refrigerant Charge 11 4 4 Electric Wi...

Page 5: ...pes 10 Never short circuit or cancel the pressure switch to prevent unit damage 11 Please firstly connect the wired controller before energization otherwise wired controller can not be used 12 Before...

Page 6: ...eries 2 We are not responsible of personal injury or equipment damage caused by improper installation and commission unnecessary service and incapable of following the rules and instructions listed in...

Page 7: ...roduct lineup is provided with capacity range from 30KBtu to 42KBtu which can be widely used in boarding house and working area and especially applicable to the place with variable load change Our com...

Page 8: ...drive up to five indoor units which can be cassette type duct type wall mounted or floor ceiling type The outdoor unit will run as long as any one indoor unit receives the running command and all indo...

Page 9: ...before outgoing 2 The parameters below are tested under rated working condition If there is any change to them please refer to the nameplate 3 The parameters of heating capacity of indoor unit for hea...

Page 10: ...orrosive gas or exhaust gas 4 Leave some space for heat exchanging and servicing so as to guarantee unit normal operation 5 Keep the indoor and outdoor units close to each other as much units close to...

Page 11: ...oor Unit and Outdoor Unit ft Liquid Gas 30K 1 4 3 8 229 6 When the outdoor unit is above maximum height difference between indoor and outdoor units is up to 49 2ft When the indoor unit is above maximu...

Page 12: ...ee match series 8 4 Installation Instruction 4 1 Outline and dimension of the outdoor unit MBRS42HPJ1OA Outline dimension and Mounting holes Fig 5 40 42 1 2 24 5 6 17 1 3 14 1 4 15 3 4 43 3 7 Unit inc...

Page 13: ...never pull any joints of the indoor unit by force otherwise the capillary pipe or other pipe may crack which then would result in leakage 2 The refrigerant pipe should be supported by brackets that i...

Page 14: ...nd plastic tape in order to prevent condensation and water leakage 2 The joints of the indoor unit should be wrapped with the insulating material and no gap is allowed on the joint of the indoor unit...

Page 15: ...rging 1 The refrigerant has been charged into the outdoor unit before shipment while additional refrigerant still need be charged into the refrigerant pipe during the field installation 2 Check if the...

Page 16: ...ot pull the power cord by force 4 The electric installation should be carried out by the technician as instructed by the local laws regulations and also this manual 5 The diameter of the power cord sh...

Page 17: ...nnect well according to the instruction 3 The electric installation should be carried out by the technician as instructed by the local laws regulations and also this manual 4 The installation location...

Page 18: ...test It may cause insufficient cooling heating capacity Is the unit get proper thermal insulation It may causecondensation and dripping Does the unit drain well It may causecondensation and dripping I...

Page 19: ...blown out again NOTICE If problem can not be solved after checking the above items please contact service center and show phenomena and models Following circumstance are not malfunction Table 11 Malfu...

Page 20: ...hat of outdoor unit indoor fault indicator will flash and conflict will be shown on the wired controller after 5 minutes Indoor unit stops to run and meanwhile change outdoor operating mode as the sam...

Page 21: ...h 3 times Outdoor ambient sensor malfunction Flash 6 times Outdoor tube sensor malfunction Flash 5 times Exhaust sensor malfunction Flash 7 times Attain the temperature of switch on Flash 8 times Freq...

Page 22: ...remote wireless controller has been replaced 4 Check if the filter screen has been set soundly 5 After long period of shutdown open the main power switch 8 hours before re operating the unit so as to...

Page 23: ...agency designated by us Warranty should meet the following requirements 1 First run of the unit should be operated by professional personnel from appointed service center 2 Only our manufactured acces...

Page 24: ...Boreal International a Watsco Inc subsidiary borealsales borealintl com www borealintl com 10300 NW 19th St 105 Doral FL 33172 786 621 8250 66129935471...

Reviews: