EN
15
Device description
www.bora.com
Power level
Switch off after hours:minutes
1
08:24
2
06:24
3
05:12
4
04:12
5
03:18
6
02:12
7
02:12
8
01:48
9
01:13
P
00:10
Tab. 4.6 Safety shut-down for power levels
Heat retention level
Switch off after hours:minutes
1
08:00
2
08:00
3
08:00
Tab. 4.7 Safety shut-down for heat retention levels
X
X
Switch the cooking zone back on (see Operating
section) if you want to put the cooking zone back into
operation.
4.4.3 Cooking zone overheating protection
All induction coils plus the cooling elements of the
electronics are equipped with overheating protection.
Before the induction coils and/or cooling elements
overheat, the overheating protection will initiate one of
the following measures:
Q
Q
The power setting
P
automatically switches to power
level
9
after 10 minutes. The control knob indicator
P
switches to
9
.
Q
Q
The set power level is reduced.
Q
Q
The cooking zones switch off automatically (see safety
shut-down of the cooking zones).
4.4.4 Childproofing feature
Thechildproofingfeaturepreventsthecooktopfrom
beingswitchedonaccidentally.Thechildproofingfeature
can only be activated when all the cooking zones are
switchedoff(seetheOperationsection).
4.3.7 Timer functions
There are two different timer functions for each cooking
zone.
Q
Q
t
appears in the control knob display.
INFO
You can set a time range of between 1 and
120 minutes for the timer functions.
Timer function
INFO
The timer function is an automatic cut-off
which automatically switches off a cooking
zone which is in use.
Short-time timer (egg timer)
INFO
The short-time timer requires the cooking
zone to be switched off and works like a
conventional egg timer.
4.3.8 Pause function
The cooking session can be temporarily interrupted (max.
10 minutes).
Q
Q
1 1
is displayed in front of the power level on the control
knob display.
4.4 Safety devices
4.4.1 Residual heat display
INFO
While
H
is displayed in the cooking zone
indicator (residual heat display), do not touch
the cooking zone or place any heat-sensitive
objects on top of it. Risk of burns and fire!
After switching it off, the cooking zone remains hot.
H
is displayed in the control knob display (residual heat
display). The display goes out after a sufficient cooling
time (temperature < 60 °C).
4.4.2 Safety shut-down
Each cooking zone is switched off automatically when the
cooking zone in the power level or heat retention level
exceeds the maximum operating duration. The control
knob display shows
H
(residual heat display).