EN
22
Installation
www.bora.com
Connecting the cooking zones when the cooktop is
installed rotated by 180°
5
4
3
2
1
Fig. 5.21 Cooking zone connection in 180° installation
[1]
Cooktop
[2]
Rear cooking zone (zone 1)
[3]
Front cooking zone (zone 2)
[4]
Rear cooking zone control knob (zone 1)
[5]
Front cooking zone control knob (zone 2)
X
X
Connect the connection on the back of the left control
knob [5] to the “zone 2” connection on the back of the
cooktop [1].
X
X
Connect the connection on the back of the right
control knob [4] to the “zone 1” connection on the
back of the cooktop [1].
X
X
Using the configuration menu, set the correct
allocation of the cooking zones in the control
knob display (see Configuration menu, 0° or 180°
installation).
Connecting the automatic extraction system
X
X
Connect the cooktop extractor to the cooktop using the
connector provided for the automatic extraction system.
5.5.6 Establishing the power connection
X
X
Observe all safety and warning information (see the
Safety chapter).
X
X
Observe all national and regional laws and regulations
as well as the supplementary regulations of the local
utility companies.
INFO
The power connection may only be established by
certified specialists. The specialist also assumes
responsibility for the proper installation and
commissioning.
The power supply line to be used (pre-assembled) must
be at least Type SiHF.
(see table Fuse protection and minimum cross-section.
Connection
Fuse protection
Minimum
cross-section
1-phase connection
1 x 25 A
2.5 mm
²
2-phase connection
2 x 16 A
2.5 mm
²
Tab. 5.4 Fuse protection and minimum cross-section
Q
Q
If the connection cable has been damaged this must
be replaced. This may only be done by an authorised
member of the After Sales Service team.
X
X
Switch off the main switch/automatic circuit breaker
before connecting the cooktop.
X
X
Secure the main switch/automatic circuit breaker
against being switched back on without permission.
X
X
Make sure the power to the appliance is disconnected.
X
X
Only connect the cooktop using a permanent
connection to a power supply cable.
1
L1
L2
2
N
PE
220 - 240 V~
220 - 240 V~
3
Fig. 5.22 Connection diagram 2-phase
1
L1
2
3
N
PE
220 - 240 V~
Fig. 5.23 Connection diagram 1-phase
X
X
Check that installation has been carried out correctly.
X
X
Switch on the main switch/automatic circuit breaker.
X
X
Put the cooktop into operation (see the Operation
chapter).
X
X
Check that all the functions are working correctly.
Summary of Contents for PKCH2