Overview

BOQU Instrument online OIW sensor is based measurement principle of ultraviolet

fluorescence method. Compared with other methods, the fluorescence method is proven to be

more efficient, fast and repeatable. It is widely used in environmental monitoring, analytical

chemistry, limnological and oceanographic biology.

The sensor has an integrated cleaning brush, which can automatic clean up air bubbles, debris,

and biofilm, therefore reduce the interference of contamination on measurement data, make the

maintenance period longer, and maintain excellent stability for long-term online use.

Typical applications include: crude and refined oil detection, leakage control at offshore oil

pipelines, monitoring of BTXE and polycyclic aromatic compound in fresh water, industrial and

municipal sewage works.

Features

RS - 485 output, Modbus protocol compatible

Integrated automatic cleaning brush, eliminating measurement interference

Use of unique optical and electronic optical filtering technique eliminates the impact of ambient

light on the measurement

UVC LED light source with low power consumption, high stability, low drift and long lifetime

No affection by particulate matter suspended in water

Introduction

Summary of Contents for BQ-OIW

Page 1: ...BQ610 B Online Controller Operation manual 1 BQ OIW Online Oil in water Sensor User Manual SHANGHAI BOQU INSTRUMENT CO LTD...

Page 2: ...rview 4 Features 4 Introduction 4 Wire Definition 6 Technical Specifications 6 Installation 7 Part List 7 Sensor Installation 7 Calibration 8 Labware and materials required 8 Maintenance 9 Maintenance...

Page 3: ...or maintenance other than which mentioned in the manual Due to non compliance with the precautions specified in this manual any fault and loss caused shall not be covered by the warranty and the manuf...

Page 4: ...measurement data make the maintenance period longer and maintain excellent stability for long term online use Typical applications include crude and refined oil detection leakage control at offshore o...

Page 5: ...BQ610 B Online Controller Operation manual 5...

Page 6: ...nce wavelength 360nm Range 5ppm NDSA equiv to 1 1ppm BTEX Resolution 0 01ppb MDL 5ppb NDSA 1ppb BTEX Linearity R 0 999 Housing IP Rating IP68 Depth Rating 30m Max Temperature Range 0 50 Interface Supp...

Page 7: ...ke sure power supply voltage is correct before turning the power on Sensor installation It is recommended to install the sensor vertically with probe facing down Considering the basic principle of sen...

Page 8: ...in deionized water transfer it to volumetric flask constant volume to 1L and get 100ppm NDSA stock solution Different concentrations of standard solution preparation Dilute 100ppm NDSA stock solution...

Page 9: ...etergent can be added in tap water to clean 2 Window surface clean the outer surface of the sensor with tap water For some stubborn dirt traditional detergent and soft cloth can be used to clean it It...

Page 10: ...2 Check according to the supporting communication protocol of the product No change in reading Cleaning brush failure 1 Check whether the brush is entangled by foreign matter if so please remove the f...

Page 11: ...jeure natural disasters social unrest war published or unpublished terrorism civil war or any government forced Damage caused due to improper use negligence accident or caused by the improper applicat...

Reviews: