DEVICE DESCRIPTION
4
VTX3
www.bopp-reuther.de
12/2018 - Z-EN-09001-id-A Exi-Gb
2.1 Device description
Vortex flowmeters measure and display the flow of flammable and non-flammable gases and
liquids. The signal converter includes either a 4...20 mA signal output with optional HART
®
communication or a bus connection. There are bus connections available according to the FISCO
model for connecting to the Foundation Fieldbus or Profibus PA. Signal converters with signal
output have a separate binary output and a separate current input.
The VTX3 W remote version consists of the SV18 flow sensor and the KV18 ..i-Ex signal converter.
2.2 Type code
The safety description code consists of the following elements*:
The remote version consisting of the flow sensor SV 18 and the signal converter KV 18 020 is
called the VTX3 W.
Figure 2-1: Safety description code for the compact version
1
Product designation
2
Type series
3
Compact version
4
Electrical signal output
free - current output 4...20 mA with optional HART
®
communication
FF - Foundation Fieldbus bus connection
PA - Profibus PA bus connection
5
Intrinsically safe supply
6
Ex - explosion-protected version
Figure 2-2: Safety description code for the signal converter of the remote version
1
Product designation
2
Type series
3
Remote version
4
Electrical signal output
free - current output 4...20 mA with optional HART
®
communication
FF - Foundation Fieldbus bus connection
PA - Profibus PA bus connection
5
Intrinsically safe supply
6
Sensor electronics VFC 020
7
Ex - explosion-protected version
Figure 2-3: Safety description code for the flow sensor of the remote version
1
Product designation
2
Type series of flow sensor