Warnings

• 

Please read the following instructions before making any instal-
lation of the actuator. The damages caused from the non-ob-
servance of these instructions are not covered in the warranty.

• 

This documentation must be kept in dry place and available for 
use.

• 

The installation and maintenance of electric actuator must be 

made only by qualified personnel.

• 

Before proceeding to the electrical connections, please make 
sure the ground wiring system works correctly.

• 

Please always check that supply voltage is included between 
the ones indicated on the label on the exterior of the actuator.

• 

Before making any maintenance on the actuator, always make 
sure to shut off the power supply.

• 

Valbia s.r.l. reserves the right to change the data and the char-
acteristics of this manual at any time and with no notice in the 
scope of a constant updating of technological improvement.

WARNING: The mechanical and electronic parts, according to

which the device is designed, are not eligible for modifications.

2.   

Transportation and storage

Valbia electric actuators are supplied in paperboard boxes which are 
of solid construction for a normal transport. Handle with care and 
keep the cover until the moment of the installation of the actuator
The storage of the actuators requires a covered, dry and ventilated 
environment, protected from temperature changes. The device must 
be stored with the cover mounted. Prior to installation, visual 
inspection is recommended to detect any anomalies caused by
transport or storage.
WARNING: Do not lift or move the actuator by the manual hand
wheel

3.  Field application

VALBIA electric actuators have been designed and tested to ball and 

butterfly valves and dampers for the industrial sector. Actuators are 

available in standard version with rotation 0°-90°. On request we can 
supply actuators with rotation 0°-180° or 0°-270°. For applications 
other than that above are needed please contact VALBIA sales 
department.

4.  Valve automation

The mechanical assembling between the electric actuator and the 
item to be automated (for example: the valve) can be done by 
direct mounting or by a mounting kit. Both the cases you can verify 
the right alignment and the correct dimensions of the part to 
transmit the power in order to avoid axial stress which can damage 
valve and actuator.

All Valbia electric actuators are in conformity of norm EN ISO 5211
DIN 3337.

In order to have a right automation of the valve, is necessary to use
a Valbia electric actuators whose range has a torque of at least
25% over the valve maximum torque.

Verify the actuator duty rating suitability with the application.

WARNING: Do not raise up or moved the motorized valve by using
the electric actuator as point of grip or hold.

5. 

Specifications and technical information (Tab. 1-2)

Documentation

Value

Object of Device

Electric Actuator

Enclosure material

Self-extinguish technopolymer

Enclosure rating

IP67

Duty cycle

75%

Duty cycle 12V version

50%

Ambient temperature range

-20°C ÷ 55°C

-4°F ÷ +131°F

Axillary limit switches

1A @ 250VAC - 1A@ 30VDC (resistive load)

Fault auxiliary contact

1 A @ 250Vac - 1 A @ 30 Vdc (resistive 

load)

Section of connections clamps’ connectors

0,5 - 1,5

Terminal block type

Plug in connector

Section of terminal block

14 - 22 AWG

2.08 - 0.32 mm

2

Minimum conductors temperature

85°C

185°F

Protection class against shock

Class I

Restriction of continue operation time (timeout)

Standard

Power supply voltage tolerance

± 10

Multiple parallel actuators wiring

Standard (*)

Cable entries

PG11 electric connections

Standard stroke

90°

Position indicator

Standard

Manual override

Standard

(*) It is important to verify that the application and its components 
are properly sized with the actuator characteristics and require-
ments.

Requested Features for UL508 Standard

UL listed file number

NMTR.E303174

Enclosure type

Type 4x Indoor Use Only

Connection conductor/wires

Listed flexible cord (ZJCZ) min. S or SJ

Green terminal block screws (max tightening 
capacity of model 100-240V AC.)

0.56 Nm

5 In. Lbs.

Black terminal block screws (max tightening 
capacity of model 100-240V AC.)

0.50 Nm

4.50 In. Lbs.

Terminal block screws (max tightening 
capacity of model 12-24V DC.)

0.50 Nm

4.50 In. Lbs.

Enclosure screws maximum tightening 
capacity

2.5 Nm

22.15 In. Lbs.

External pollution degree

3

Internal pollution degree

2

Overvoltage category

2

Product in conformity with the European Community norms
LOW VOLTAGE 2014/35/UE (LVD)
ELECTROMAGNETIC COMPATIBILITY 2014/30/UE (EMC)
MACHINERY 2006/42/CE
ROHS 2011/65/UE
REGULATION No 1907/2006 (REACH)
Use copper (CU) conductor

3

IOM |

 85 SERIES ON/OFF ELECTRIC ACTUATORS

Summary of Contents for 85 Series

Page 1: ...IOM 85 SERIES ON OFF ELECTRIC ACTUATORS NORTH AMERICA...

Page 2: ...Instruction 4 6 1 Electrical Connection 5 6 2 Auxiliary Switches Wiring 6 6 3 Potentiometer Wirings Optional 6 6 4 Heating Resistors 6 6 5 Signal Lamp Unit 6 7 6 6 Setting Actuator Stop Positions 7 6...

Page 3: ...orrect dimensions of the part to transmit the power in order to avoid axial stress which can damage valve and actuator All Valbia electric actuators are in conformity of norm EN ISO 5211 DIN 3337 In o...

Page 4: ...A Absorbed Power H Version 60 72 VA 60 72 VA 75 96 VA Nominal Tension L Version 12V AC DC 24V AC DC 12V AC DC 24V AC DC 12V AC DC 24V AC DC Current Absorbed L Version 3 8 2 85A 1 8 1 2A 3 8 2 85A 1 8...

Page 5: ...hould be followed for proper wiring of the actuators is shown in paragraph 10 0 and it can be found also on the label inside the upper cover Please follow the maximum allowed electrical rating values...

Page 6: ...6 3 Potentiometer wirings optional Fig 5 The actuator with potentiometer includes an extra terminal block POT Fig 5 which grants the possibility to use the re sistive infomation concerning the actuato...

Page 7: ...graph 7 0 5 Loosen the set screw in the cam 1 black color and rotate the cam until it pushes the limit switch POS2 and until the click of the electromechanical micro switch Then tighten the set cam sc...

Page 8: ...itches Battery operation is enabled after a delay of about 1 sec it is instan taneous only if the emergency operation is consistent with the operation in progress for example when the actuator is clos...

Page 9: ...s components if not usable must be demolished and divided up according to the type of product All this helps collection disposal and recycling centers and minimizes the environmental impact that this...

Page 10: ...NORTH AMERICA CORPORATE OFFICE 750 IMPERIAL CT CHARLOTTE NC 28273 PH 704 412 9031 FAX 704 412 9032 sales bonominorthamerica com...

Reviews: