IMPORTANT RECOMMENDATIONS

 

The installation should be entrusted to approved contractors and 

comply with all current regulations.

 

Before locating the unit ensure that the air circulation and volume 

are sufficient to allow normal cooling of the condenser and 
compressor.

 

Avoid installing the cabinet near major sources of heat or in direct 

sunlight.

 

Note that too high an ambient operating temperature can reduce 

performance

 

When connecting electrically earth continuity must be maintained 

between the unit and the supply socket.

 

The supply cable that is fitted is a specific part and should only be 

replaced with an original part. Ensure that the plug is easily accessible 
as a means of electrical isolation.

 

Protection against electrical overload or faults is the responsibility of 

the installer. Ensure that a circuit breaker or fuses are fitted in the 
supply circuit (See data plate).

 

All operations on the electrical or refrigeration circuits, including 

cleaning should only be undertaken with the unit DISCONNECTED 
(unplugged)

 

The air cooled compressor condenser must be cleaned regularly 

(Every 3 to 6 months).

 

The unit should not be sprayed or splashed with water:

. Do not use a jet wash on the exterior or technical parts of the
unit.
. The equipment must not be installed in the fresh air or exposed
to the elements.

 

Correct functioning depends on the factory fitted safety systems being 

respected. No responsibility can be accepted for malfunctions that 
result from modifications undertaken on our equipment.

 

The manufacturer can not be held responsible so the equipment be 

used for anything other than the purpose it was designed for.

A L L   S P E C I F I C AT I O N S   A N D  C H A R A C T E R I ST I C S  I N   T H I S

MANUAL MAY BE SUBJ ECT TO CHANGE WITHOUT NOTICE

Summary of Contents for SR 1200GR900

Page 1: ...I 0606 REFRIGERATED BASES TOQUE BLANCHE GRANDE CARTE INSTALLATION MANUAL MANUFACTURERS SPECIFICATION BONNET GRANDE CUISINE Rue des Frères Lumière Z I Mitry Compans 77292 MITRY MORY cedex Tél 01 60 93 70 00 Fax 01 60 93 70 43 9 ...

Page 2: ...e responsibility of the installer Ensure that a circuit breaker or fuses are fitted in the supply circuit See data plate All operations on the electrical or refrigeration circuits including cleaning should only be undertaken with the unit DISCONNECTED unplugged The air cooled compressor condenser must be cleaned regularly Every 3 to 6 months The unit should not be sprayed or splashed with water Do...

Page 3: ...BLANCHE GRANDE CARTE 1 Technical Characteristics 2 2 Identification plate 4 3 Installation General features 5 4 Installation Connections 9 BONNET GRANDE CUISINE Rue des Frères Lumière Z I Mitry Compans 77292 MITRY MORY cedex Tél 01 60 93 70 00 Fax 01 60 93 70 43 ...

Page 4: ...30 x 620 PACKAGING mm Height 900 900 Width 1300 1700 Depth 800 800 WEIGHT KG 80 120 BASE COMPRISES Refrigeration unit compartment 1 GN 21 1 door 2 2 200 mm door 1 ELECTRICITY Power kW Single ph 230V a c 0 45 0 45 Intensity A Single ph 230V a c 4 4 DRAIN 20mm Ø PVC drain outlet REFRIGERATION POWER at 15 55 Power Watts 321 REQUIRED REFRIGERATION POWER at 15 55 Power Watts 321 ELECTRICAL CONNECTION I...

Page 5: ...740 PACKAGING mm Height 900 900 900 Width 1300 1700 2100 Depth 800 800 800 WEIGHT KG 110 130 180 BASE COMPRISES Refrigeration unit compartment 1 1 GN 1 1 door GN 2 1 door 1 2 2 Cupboard 1 ELECTRICITY Power kW Single ph 230V a c 0 45 0 45 0 45 Intensity A Single ph 230V a c 4 4 4 DRAIN 20mm Ø PVC drain outlet REFRIGERATION POWER at 15 55 Power Watts 321 321 REQUIRED REFRIGERATION POWER at 15 55 Pow...

Page 6: ...ignation N SERIE Tension V Hz Puissance W Classe Refrigérant g Eclairage W Dégivrage W W P Max b Réévap d eau A g A Dégivrage Réévap d eau W W Classe W Hz Date Refrigérant P Max Eclairage b N SERIE Puissance Tension Désignation Type W V g A Dégivrage Réévap d eau W W Classe W Hz Date Refrigérant P Max Eclairage b N SERIE Puissance Tension Désignation Type W V g A Dégivrage Réévap d eau W W Classe ...

Page 7: ...n direct sunlight or adjacent to sources of heat z The manufacturer certifies that the packing conforms to directive 94 62 CE of 20 12 94 and requests that the final recipient respects the directive with regard to recycling or reuse of the packaging materials 3 2 HANDLING The appliance should only be handled with specialised lifting equipment Should the appliance need to be transported it must be ...

Page 8: ...ng it For re assembly reverse the above order of operation 2 5 ASSEMBLY OF ITEMS ON A REFRIGERATED BASE Position the front and rear fixing brackets in the indicated positions using two 4 8mm Ø rivets One bracket for a 400mm module and two for an 800 or 1200 unit 400 centres for an 800 and 800 for a 1200 TOQUE BLANCHE SERIES COOKING TOPS for units not incorporating drainage Screw Front of the refri...

Page 9: ...SERIES COOKING TOPS for units not incorporating drainage GRANDE CARTE SERIES COOKING TOPS Including items with drainage Front of the refrigerated base Front of the refrigerated base Front of the refrigerated base Front of the refrigerated base Front of the refrigerated base Front of the refrigerated base ...

Page 10: ...as follows Toque Blanche Grande Carte A 710 900 B 620 740 C 70 140 5 Fix appliances to the base on the rear brackets usingthree screws HM5 X 10 5mmø washers 5 Connect the units together at the rear flue vents And at the front behind the facia Fixing holes ...

Page 11: ...r compartment door IMPORTANT Only electrical cable type HO 7 RNF with cross section 3 x 1 5 mm2 should be used Provide a suitable isolating device with contact separation of at least 3mm in accordance with current regulations The installation comply with current applicable national legislation for France standard NF 15 100 The appliance must be connected to the earth The various electrical applian...

Page 12: ...he drain connection should comply with current guidelines especially concerning cross contamination connection with an air gap is recommended a direct connection may not conform to local regulations The drain should be trapped to avoid odours Recommended solution 50 mm 100 mm Ø trapped tundish trapped below slab or gully ...

Reviews: