INO 36 DISHWASHER Code NU271700-11/97-Ind.B-01/99
Chap.5 - Page 1
SERVICE - SERVICE - SERVICE - SERVICE - SERVICE - SERVICE -
To ensure the guarantee of this equipment, you must carry out the following service operations :
* End of operation (2nd part)
_____________________________________________________________
* Cut off the electric power
* Close the water supply
* Check the levels of the containers of :
at the main circuit-breaker.
- rinse product
- detergent (exterior appliance)
- regenerating salts (option).
Complete if necessary
* Let the door open to favour the drying of the
dishwasher.
* Access to the rinse product meter and regenerating salts vat (option)
- Rinse meter : located behind the front lower panel.
- Regenerating salts vat(interior tank)
*
Rinse
product
meter
operation :
The meter flowrate setting is made by using
the meter setting screw.
* First setting according to the manufacturer indications.
Correct if necessary according to the results obtained on the crockery.
Surface-active product meter is
set in factory. It is possible to
modify the setting by removing the
lower cover.
- Screw to reduce the injected quantity.
- Unscrew to increase the injected quantity.
W
ARNING
: never screw or unscrew at the
maximum.
* If the rinse product container is completely empty
prime again the meter after filling.
- Prime the metering system (control panel) by starting very short wash cycles every 10" to 15".