background image

 

Page 10 

3BE390692NM – 10/10 

 

 

BONNET GRANDE CUISINE 
Registered Office: 
Rue des Frères Lumière - Z.I Mitry Compans 
77292 MITRY MORY Cedex

 

 

5.2.2 AFTER SEPTEMBER 29TH, 2010 : FROM N° P2751622 6C 

 

According the country of installation and the category of the appliance (indicated on the firm plate), the 

adaptation from one gas to another may require 1 operation: 

 

CI:  

Change of nozzles (burners) 

(See 4.4) 

 
PROCEDURE: 
 

On the firm plate, check: 

- The category (ies) of the equipment. 
- The gas and pressure for which it is adjusted. 

In the following chart, select: 

- The country concerned. 
- The gas and the category of the appliance (see above). 
- The gas and the pressure for which the appliance is going to be adjusted. 
- Note and carry out the required operations. 
- Replace the adjustment plate (code: 308 875), and mark the new gas used. 

 

Countries 

concerned 

Category and GAS OF ORIGIN 

(or new gas) 

NEW GAS and Category 

(or gas of origin) 

Required 

operations 

 

Category 

Gas 

P (mbar) 

Gas 

P (mbar) 

Catégorie 

 

Austria 

I

2H

 

G20 

20 

G30 / G31

 

50 

I

3B/P

 / 

I

3P

 

 

 

I

3B/P

 

G30 

50 

G31

 

50 

I

3P

 

CI 

Finland - Norway 

I

2H

 

G20 

20 

G30 / G31

 

30 

I

3B/P

 

CI 

Sweden – Denmark 

I

3B/P

 

G30 

30 

G31

 

30 

I

3B/P

 

CI 

Czech Republic  

I

2H

 

G20 

20 

G30 / G31

 

28-30/37/50 

I

3+

 / 

I

3B/P

 / 

I

3P

 

 

I

3B/P

 / 

I

3+

 

G30 

28-30 

G31

 

30-37-50 

I

3P

 

CI 

 

I

3P

 

G31 

37 

G31

 

50 

I

3P

 

CI 

Spain 

I

2H

 

G20 

20 

G30 / G31

 

28-30/37/50 

I

3+

 / 

I

3P

 

United Kingdom 

I

3+

 

G30 

28-30 

G31

 

37-50 

I

3P

 

CI 

 

I

3P

 

G31 

37 

G31

 

50 

I

3P

 

CI 

Germany 

I

2ELL

 

G20 

20 

G25

 

20 

CI 

Luxemburg 

I

2ELL

 

G25 / G25 

20 / 25 

G30 / G31

 

50 

I

3B/P

 / 

I

3P

 

CI 

 

I

3B/P

 

G30 

50 

G31

 

50 

I

3P

 

CI 

Switzerland 

I

2H

 

G20 

20 

G30 / G31

 

28-30/37/50 

I

3+

 / 

I

3B/P

 / 

I

3P

 

CI 

 

I

3+

 / 

I

3B/P

 

G30 

28-30 / 50 

G31

 

37-50 

I

3P

 

CI 

 

I

3+

 

G30 

28-30 

G30

 

50 

I

3B/P

 

 

I

3P

 

G31 

37 

G31

 

50 

I

3P

 

Greece  

I

2H

 

G20 

20 

G30 / G31

 

28-30/37 

I

3+

 / 

I

3B/P

 / 

I

3P

 

CI 

Italy 

I

3+

 / 

I

3B/P

 

G30 

28-30 

G31

 

37 

I

3P

 

CI 

Ireland  

I

2H

 

G20 

20 

G30 / G31

 

28-30/37 

I

3+

 / 

I

3P

 

CI 

Portugal 

I

3+

 

G30 

28-30 

G31

 

37 

I

3P

 

CI 

Netherlands 

I

2L

 

G25 

25 

G30 / G31

 

28-30/50 

I

3B/P

 / 

I

3P

 

CI 

 

I

3B/P

 

G30 

30 

G31

 

50 

I

3P

 

CI 

France 

I

2Esi

 

G20 

20 

G25

 

25 

CI 

 

I

3+

 

G30 

28-30 

G31

 

37/50 

I

3P

 

CI 

 

I

3P

 

G31 

37 

G31

 

50 

I

3P

 

Belgium 

I

2E(s)B

 

G20 / G25 

20 / 25 

G30 / G31

 

28-30/37 

I

3+

 / 

I

3P

 

CI 

 

I

3+

 

G30 

28-30 

G31

 

37 

I

3P

 

CI 

* The category change is only to be carried out under the responsibility of the Company T.G.C.P. or our local agent. 

Summary of Contents for Equator 6

Page 1: ... not undertake the required maintenance operations our installation and service network is available to provide you with a personalized contract WARNING The product delivered to you complies with current standards If any modifications are made the manufacturer cannot accept any responsibility whatsoever The manufacturer can not be held responsible in the event of an incorrect use of the appliance ...

Page 2: ... FAILURES 7 5 CHANGING THE EQUIPMENT FROM ONE GAS TO ANOTHER 8 5 1 LISTOFAUTHORISEDGASES PRESSSURESACCORDINGTOCATEGORIESANDCOUNTRIES 8 5 2 CHANGE OVER FROM ONE GAS TO ANOTHER 9 5 3 GAS FLOW RATES AND POWERS 11 5 4 CHART OF NOZZLES 11 6 MAINTENANCE 14 6 1 SERVICING THE CONDENSER 14 7 VERIFICATION OF TEMPERATURE SENSORS 15 8 DOOR ADJUSTMENT AND CLOSING 17 8 1 8 AND 12 LEVEL OVENS 17 8 2 20 LEVEL OVE...

Page 3: ...S 00108 CLEANINGS 00058 INSTAL ASS CODE AAAA PARAMETER SETTING 0847 PARAMETER SETTING 061 RETURN LANGUAGE FR UK ES NL C F C DISPLAY SIMPLE DETAILED MODIFICATION CODE AAAA FREE INTER LOCK CONTRAST BUZZER Detail DUCK BREAST SHORT OPTIMAL COLORE COLORE SAIGNNAT ROSE 2H34MN AUTO COOKING 01 STOP 230 AUTO COOKING 01 ROAST BEEF MODE DRY 230 c 195 c 02H33MN 00H02MN 65 c 12 8 c 20 STOP CLEANING 04 CLEANING...

Page 4: ...14 15 16 and 17 Facia board Relay connecting ribbon Warning To insert the connecting ribbon between the UC card and the facia card take care to support the printed circuit under the connector Fuse This only protects against a lighting failure Connection of the generator sensor 1 4 3 2 Connection of a core probe connector Connection of a capacity sensor Motor supply inlet Warning In case of a gas P...

Page 5: ...s 0 Celsius degrees if it shows 32 Fahrenheit degrees When you change the min UC relay card there are two possibilities Keep the customer parameters counters C F si mple detailed display Recuperate one or more memory components from the old card and place them on the new card in the same support and in the same way 3A15 25 1A E4 GND E5 E6 GND E7 E8 GND E9 E10 GND 24 23 26 22 7 8 9 10 12 6 5 4 Set ...

Page 6: ...ERV By means of the selection button position the cursor on KEY Validate with the Validation button The parameter 0 1 2 of the key can be modified with the selection button Configuration key Technical code Designation C01 C02 C03 C04 C05 C06 C07 C08 C09 C10 EQ4 81 1 PC Electric Précisio oven 6 GN1 1 EQ4 121 1 PC Electric Précisio oven 10 GN1 1 1 0 1 3 1 1 0 0 0 0 EQ4 201 1 PC Electric Précisio ove...

Page 7: ...nguage selection FR ES NL UK Choice between T in C or F Choice of permanent display SIMPLE or DETAILED This enables the Chef after he has entered a code to change from a FREE mode to the INTER and LOCK modes limiting the possibility of modification of personalised recipes PARAMETER SETTING 061 RETURN LANGUAGE FR UK ES NL C F C DISPLAY SIMPLE DETAILED MODIFICATION CODE AAAA FREE INTER LOCK CONTRAST...

Page 8: ...eam boiler at 110 C E70 Short circuited boiler sensor E71 Cut boiler sensor Other failures E42 Maximum temperature within the electronic facia exceeded E43 Saturated steam inlet activated more than 30 seconds in steam mode Choked condenser nozzle condenser supplied with hot water or insufficient flow rate E45 Inoperative boiler drainage E46 Defective communication bus I2C E47 Saturated USB flash d...

Page 9: ... G20 20 I3B P G30 and G31 50 I3P G31 50 Finland Denmark I2H G20 20 Sweden Norway I3B P G30 and G31 30 Czech Republic I2H G20 20 I3B P G30 and G31 30 I3 G30 G31 28 30 37 I3P G31 37 and 50 Spain I2H G20 20 United Kingdom I3 G30 G31 28 30 37 I3P G31 37 and 50 Germany G20 20 Luxemburg I2ELL G25 20 I3B P G30 and G31 30 I3P G31 50 Switzerland I2H G20 20 I3B P G30 and G31 50 I3 G30 G31 28 30 37 I3P G31 3...

Page 10: ... operations Category Gas P mbar Gas P mbar Category Austria I2H G20 20 G30 G31 50 I3B P I3P CV CI CR I3B P G30 50 G31 50 I3P CR Finland Norway I2H G20 20 G30 G31 30 I3B P CV CI CR Sweden Denmark I3B P G30 30 G31 30 I3B P Czech Republic I2H G20 20 G30 G31 28 30 37 50 I3 I3B P I3P CV CI CR I3B P I3 G30 28 30 G31 30 37 50 I3P CR I3P G31 37 G31 50 I3P Spain I2H G20 20 G30 G31 28 30 37 50 I3 I3P CV CI ...

Page 11: ...30 G31 50 I3B P I3P I3B P G30 50 G31 50 I3P CI Finland Norway I2H G20 20 G30 G31 30 I3B P CI Sweden Denmark I3B P G30 30 G31 30 I3B P CI Czech Republic I2H G20 20 G30 G31 28 30 37 50 I3 I3B P I3P I3B P I3 G30 28 30 G31 30 37 50 I3P CI I3P G31 37 G31 50 I3P CI Spain I2H G20 20 G30 G31 28 30 37 50 I3 I3P United Kingdom I3 G30 28 30 G31 37 50 I3P CI I3P G31 37 G31 50 I3P CI Germany I2ELL G20 20 G25 2...

Page 12: ...0 or 37 4 6 147 773 or 50 1 5 7 368 550 1 groove Burner G P L G30 30 or 50 1 5 7 368 550 1 groove 9 2 147 773 20 level ovens GASES NOZZLES Régl vanne de Designation Pression Qty Qty Code Marking d air régulation Family Type mbar dry steam 1 100e stamped d stamped G20 20 2 1 8 5 368 551 3 5 147 772 Natural gas G25 20 or 25 2 1 No nozzle 2 6 147 772 G31 30 or 37 4 6 147 773 or 50 2 1 5 7 368 550 1 g...

Page 13: ... or 25 1 8 5 368 891 1 groove G31 30 or 37 or 50 1 4 1 368 893 3 grooves Burner L P G G30 30 or 50 1 3 75 368 892 2 grooves 20 level ovens GASES INJECTEURS Designation Pressure Qty Qty Code Marking Family Type mbar dry steam 1 100e stamped G20 20 2 1 6 1 368 890 0 groove Natural gas G25 20 ou 25 2 1 8 5 368 891 1 groove G31 30 ou 37 ou 50 2 1 4 1 368 893 3 grooves Burner L P G G30 30 ou 50 2 1 3 7...

Page 14: ...0692NM 10 10 BONNET GRANDE CUISINE Registered Office Rue des Frères Lumière Z I Mitry Compans 77292 MITRY MORY Cedex Positioning of the nozzle and the air distancing ring Regulating valve Air distancing ring Nozzle ...

Page 15: ...ent service twice a year by qualified personnel from our company and especially Dismantle burners checking and cleaning venturis Clean the nozzles Clean the ventilating apertures Investigate possible leaks Check controls regulation and safety systems Check the hydraulic circuit and condenser 6 1 SERVICING THE CONDENSER The water injection nozzle and the temperature sensor are to be checked and cle...

Page 16: ...20 16 120 55 120 93 121 32 121 70 122 09 122 47 122 86 60 123 24 123 62 124 01 124 39 124 77 125 16 125 54 125 92 126 31 126 69 70 127 07 127 45 127 84 128 22 128 60 128 98 129 37 129 75 130 13 130 51 80 130 89 131 27 131 66 132 04 132 42 132 80 133 18 133 56 133 94 134 32 90 134 70 135 08 135 46 135 84 136 22 136 60 136 98 137 36 137 74 138 12 100 138 50 138 88 139 26 139 64 140 02 140 39 140 77 ...

Page 17: ...of 164 C Find the intersection of the line 160 C and the col umn 4 C The reading shows 162 53 Ohms Check Ω PT100 MΩ Check sensor resistance with an ohmmeter gauged at 200 ohms less than 107 ohms for 20 Check the sensor insulation between one of the leads and the metal part with the ohmmeter gauged at 20 megohms a value over 15 megohms Check the continuity between the screen and the metal part of t...

Page 18: ...ixation screws of the upper hinge on the oven Level the door tighten and block the screws Loosen the fixation screw of the upper hinge on the door Push the door against the seal so that tightness is perfect Warning It is useless to squeeze the seal flat it will not result in better tightness Block the fixation screw of the hinge Bring the upper distance between the door and the capacity to the low...

Page 19: ...groove Distance between the top and the piston tip Distance between the top and the groove bottom The distance between the top of the oven and the closing hook must be 1 to 2 mm greater than the distance between the top of the door and the piston tip If not loosen the closing hook screw and adjust the distance 8 2 20 LEVEL OVENS Make sure that the oven is properly secured to the floor Level the ov...

Page 20: ... the fixation screw of the upper hinge on the door Push the door against the seal so that tightness is perfect Warning It is useless to squeeze the seal flat it will not result in better tightness Block the fixation screw of the hinge Bring the upper distance between the door and the capacity to the lower part of the door by loosening the fixation screws of the lower hinge Screw ...

Page 21: ...ling lime scale The main consequence of this wear results in steam leaks in the way of the driving shaft in a modification of cooking results coloration drying PROCEDURE FOR CHANGING THE GASKET Open the ventilation duct Unscrew the holding screw of the water deflector and remove the deflector Install the hub puller 3 points with flat tips and extract the turbine Remove the gasket Screw deflector D...

Page 22: ...ing the rings easier Assemble the ring with the gasket assembly code 145 587 Install the assembly on the driving shaft Rotate the driving shaft before putting the turbine back in place Warning Check gasket driving shaft co axiality Run the motors before reassembling the turbines to check proper positioning of the ring and the gasket they must not rotate together with the driving shaft Reassembly c...

Page 23: ... 60 Hz contactor 300700 Anti interference relay 300769 95 C thermostat 301048 60 C condenser thermostat 301065 Manual reseting 320 C thermostat nut 301066 Pressure switch B1 55 41 301373 PT100 sensor diameter 4 350 in length 301456 2 points PT 100 regulating sensor 301471 Gas generator probe 301479 Circular heating element round flange 9KW diameter 340 302229 Circular heating element round flange ...

Page 24: ...19 Safety box 577DBC 310324 Lever solenoid valve 220V 50 60 Hz 314356 Motorised valve 3 4 230V 50 60 Hz female 314359 Motorised valve 1 230V 50 60 Hz female 314360 Pump UP 60 321 rate 150 L mn 314361 Inlet outlet 1 way solenoid valve 10 L min 314362 10 2 x 15 diameter 2 mm thick metal asbestos plastic gasket 318033 Heating resistance capacity immersion heater gasket 366461 Lighting glass sheet gas...

Page 25: ...ed for the BONNET technical network MAINTENANCE 06 RETURN NEXT SERVICING 00202H VOLTAGE ON 00548H DRY 00100H STEAM 00200H COMBI 00080H COOLINGS 00092 DOOR OPENINGS 00108 CLEANINGS 00058 INSTAL ASS CODE AAAA PARAMETER SETTING 0847 For access to the INSTAL ASS menu enter the BASS Bonnet ASS code Bring the vertical lift to the same level lower knurl Validate with the upper knurl the cursor a dash und...

Page 26: ...by default Remember to RESET by validating this line when servicing in order to enable the customer s counter to restart at the value adjusted in the ASS frequency INSTAL ASS 062 RETURN COUNTERS ACTIV SAFETY INLET 00000 TIME T is over 70 C 00000 NUMBER OF AUTO RESETS 00001 PARAMETER SETTING KEY 1002010000 ASS FREQUENCY 00750H TECHNICAL ASSISTANCE OVEN ADDRESS AZBK RESET NEXT SERVICING Access to th...

Page 27: ...tivation of inlets outlets Bring the vertical lift opposite the outlet to be checked lower knurl For all that concerns the contactor each activation of the upper knurl results in the actuation of the outlet for 0 5 S with drop out afterwards in order to check that the coil is not stuck and operates properly For all that concerns the ventilation Line 14 and line 17 line 14 Activation of 7 and 14 fo...

Page 28: ...1 TECHNICAL ASSISTANCE 0622 RETURN 0 1 OUTLETS E3 92 E5 Condenser inlet If 0 clicson opened temperature 60 If 1 clicson closed temperature 60 E4 Door sensor If 0 door opened If 1 door closed E6 Gas safety inlet If 0 Burner pilot flame burning If 1 Burner pilot flame out defective ignition E7 Steam generator water level sensor If 0 generator sensor uncovered If 1 generator sensor immersed E8 Inlet ...

Reviews: