![bonitron M3575R Customer Reference Manual Download Page 13](http://html.mh-extra.com/html/bonitron/m3575r/m3575r_customer-reference-manual_2787120013.webp)
User’s Manual
13
3.
I
NSTALLATION
I
NSTRUCTIONS
WARNING!
Installation and/or removal of this product should only be performed by a
qualified electrician in accordance with National Electrical Code or local
codes and regulations.
Proper installation of the Model M3575R Resistive Braking Load Module should be
accomplished following the steps outlined below. Be sure to refer to the AC Drive and/or
Braking Kit instruction manual as these steps are performed. Please direct all installation
inquiries that may arise during the installation and startup of this braking product to the
equipment supplier or system integrator.
3.1.
E
NVIRONMENT
The module should be installed in an area protected from moisture and falling debris.
Buildup of dust or dirt on the resistor can be a fire hazard. Operating in a wet
environment can pose a shock hazard.
See Table 2-5 for the recommended temperature range for operating or storing this
module.
3.2.
U
NPACKING
Upon receipt of this product, please verify that the product received matches the
product that was ordered and that there is no obvious physical damage to the unit. If
the wrong product was received or the product is damaged in any way, please contact
the supplier from which the product was purchased.
Figure 3-1: M3575R Mounting Orientation
C
B
A
VERTICAL SURFACE
HORIZONTAL TO FLOOR
UP
UP
HANGING UNDERSIDE
UP
HORIZONTAL SURFACE
3.3.
M
OUNTING
The installation site for the module should be chosen with several considerations in
mind:
The mounting surface must be non-flammable, as the unit will generate high
surface temperatures during typical operation.
The unit requires a minimum clearance of two (2) inches in all directions around it
when mounted near a non-heat source. When mounting near a second M3575R
or other heat source, a minimum of six (6) inches of clearance MUST be allowed
between the two.
Once the installation site has been selected as outlined above, the unit should be
mounted in place. The M3575R must be properly oriented for proper air flow through
Dwg: 070131 Rev: 20070524
Summary of Contents for M3575R
Page 6: ...M3575R 6 This page intentionally left blank ...
Page 16: ...M3575R 16 Figure 3 2 Typical Braking Resistor Field Connections Dwg 070076 Rev 20070418 ...
Page 20: ...M3575R 20 This page intentionally left blank ...
Page 29: ...User s Manual 29 NOTES ...
Page 30: ...M3575R 30 This page intentionally left blank ...
Page 31: ......