Böning AHD 903BS Manual Download Page 1

1

bugvs-e.mcd

BOW THRUSTER CONTROL WITH

VARIABLE PITCH PROPELLER

AHD 903BS

 1   3    5   7   9

 1   3    5   7   9

2   4   6    8

2   4   6    8

11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

1 0 1 2 1 4 1 6 18 20 22 24 26 28 30 32 34 36 38 40

1 0 1 2 1 4 1 6 18 20 22 24 26 28 30 32 34 36 38 40

40- pole ribbon cable

40- pole ribbon cable

14-pole ribbon cable

14-pole ribbon cable

pluggable on both sides

pluggable on both sides

Covering

Covering

pluggable on both sides

pluggable on both sides

1   2   3   4   5   6   7   8

1   2   3   4   5   6   7   8

Transfer station

Transfer station

Analog station AHD 903-15

Analog station AHD 903-15

Relay station AHD 903R

Output unit AHD 903IP

Rail TS 32 or 35

Accelerator

Wing pt.

Bridge

Wing stb.

4

 w

ir

e

s

 i

n

c

l.

 p

o

w

e

s

u

p

p

ly

Actual-value-registration

For display at the
control desks

Rail TS 32 or 35

Impulse length controlled magnetic valves

Development, manufacturing, service for shipping and industry
Böning Automationstechnologie GmbH & Co. KG • Am Steenöver 4 • D-27777 Ganderkesee
Phone: +49(0)4221 9475-0 • Fax: +49(0)4221 9475-22 • Internet: www.boening.com • E-Mail: [email protected]

Summary of Contents for AHD 903BS

Page 1: ...ng pluggable on both sides pluggable on both sides 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Transfer station Transfer station Analog station AHD 903 15 Analog station AHD 903 15 Relay station AHD 903R Output unit AHD 903IP Rail TS 32 or 35 Accelerator Wing pt Bridge Wing stb 4 wires incl power supply Actual value registration For display at the control desks Rail TS 32 or 35 Impulse length controlled magne...

Page 2: ...Thruster with Adjustable Pitch Propeller AHD 903BS 903bsi e Contents Page 1 Construction 3 2 Control Units 3 3 Bow Thruster 4 4 Failure Report 4 5 Commissioning 4 Terminal Diagram 8 Dimensional Drawing 9 Technical Data 9 ...

Page 3: ...r a 3 point after running controller by comparison of target joystick and actual value controller at the bow thruster If during operation driving shall be continued from one of the wing control units the selector switch for operation at the main control unit has to be switched into the appropriate position port or starboard Then the takeover button at the wing control unit has to be pushed which c...

Page 4: ...iations caused by oil leakages within the range of the impulse length activation or within the close up range The solenoid valves do not open before a minimum current is reached The minimum current is usually 20 of the rated current This minimum current can be adjusted with a special DIP switch a Level 1 16 minimum current which means that the valve is still closed at the start of the control rang...

Page 5: ...5 Then the target value controllers joysticks of all three control units are switched into position max negative propeller angle lowest position 6 After checking the three previous instructions again now the relevant controller positions for this limiting position can be stored durably For this purpose the takeover button in the bridge control unit has to be pushed for app 1 sec After disengaging ...

Page 6: ...the slider has to be higher than in zero position or a wrong position of the selector switch operation whose labelling has a different meaning during programming Anyway in case of such a mistake the whole programming procedure has to be repeated The same applies if there is a power failure during the programming phase If necessary a new adjustment can be done later at any time Here it is also poss...

Page 7: ...tal value 32 SW1 S3 16 ON Byte Low No proportion SW2 S1 8 OFF Byte High Proportion of total value 8 SW2 S2 4 OFF Byte High Proportion of total value 4 SW2 S3 2 ON Byte low No proportion SW2 S4 1 OFF Byte High Proportion of total value 1 Therefore the total value of the close up range is 45 The min current for the proportional solenoid valves is adjusted with the SW 1 switch 1 ON Imin 16 of target ...

Page 8: ...Lamp test In progr m ode bridge 0 Position Nom position Nom position Nom position Takeover Takeover Takeover Takeover Takeover Takeover Operation Operation Operation BRIDGE BB Wing Panel STB Wing Panel Adjustable angle IMPORTANT All potentiometers 2 2 5 kOhm actual value At max positive angle the voltage at all potentio meter sliders has to be app 10 12 Volts Act value Indication Start release Fai...

Page 9: ...nit AHD 903IP Rail TS 35 or 35 1 1 0 d e e p 60 1 2 3 4 5 6 7 8 1 1 2 2 3 3 4 SW 1 SW 2 View of Output Unit AHD 903IP from above without covering DIP switch SW 1 SW2 for adjustment of the near limiting value range Control for bow thruster AHD 903BS with adjustable pitch propeller TECHNICAL DATA Power supply Power cons of electronics Perm load of relay contacts Perm load of transistors Serial inter...