![BOND MANUFACTURING Gatewood 50436 Owner'S Manual Download Page 11](http://html1.mh-extra.com/html/bond-manufacturing/gatewood-50436/gatewood-50436_owners-manual_2786726011.webp)
1-866-771-2663 | Page 11
To Light
To Extinguish
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor
area. Connect the propane gas tank to the regulator and turn the valve on the unit to the “off”
position. Brush a soap and water mixture on all connections. Turn the gas supply on; if bubbles
occur on any connection there may be a leak.
If you smell gas or a leak is discovered turn the
gas valve off, disconnect propane gas tank and do not use the appliance until the leak is
repaired.
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion
you must replace the hose (if applicable).
Pumice stones/lava rocks/LavaGlass
™
could pop up and
strike somebody’s face during the process of lighting this unit; stand away from the unit for the first
20 minutes after igniting. Flame height should be a yellow/blue color between 2 - 10 inches in height.
Wait 5 minutes after extinguishing flame prior to placing a lid (if applicable) or protective cover on
heating item.
1. Make sure the control knob (K) is in the “off” position.
2. Open the door on the door panel (H) and slowly open the valve on the propane gas tank by
turning the knob counterclockwise.
3. Push in the control knob (K) and turn counterclockwise to the “LOW” position. Keep holding
down the control knob (K) to allow gas to flow for 15 seconds prior to lighting.
4. While holding down the control knob (K) press down the igniter (L) to spark a flame and light
the fire table. While pressing the igniter (L) you should hear a clicking sound. If needed keep the
control knob (K) and igniter (L) pressed down until the fire table lights.
5. If ignition doesn’t occur within a few seconds release the control knob (K) and rotate to the “OFF”
position. Wait for 5 minutes for gas to clear and then repeat the above lighting instructions.
6. Once the fire product is lit, the flame intensity may be controlled by turning the control knob (K)
between the “LOW” and “HIGH” positions.
7. Close the door on the door panel (H) on the body.
1. Turn control knob (K) to the “HIGH” position; let the knob pop up and continue turning the control
knob (K) to the “OFF” position.
2. Close the cylinder valve on the propane gas tank if you don’t intend to use it for a long time.
OPERATION