D
ELUXE
W
ALL
F
URNACE
Page 8
Gas & Electrical
Gas & Electr
G
AS
ical
Important note
When connecting the gas supply inlet
pipe to the gas valve, hold the
connection nipple on the valve with a
spanner while tightening the inlet pipe
compression nut. This ensures the
nipple is not over tightened. Climate
Technologies is not responsible for a
cracked gas valve casting due to over
tightening during the installation. The
replacement valve is therefore not
covered by warranty.
1.
Natural Gas:
The connection on heater
is a ½”
BSP compression fitting. Flare
the copper connection tube using a flare
nut to connect to the unit.
2. Use gas copper pipe to AS 1432 Type B
or other approved gas piping.
3. Have a licensed gas fitter install the gas
supply pipe. The gas supply can be
plumbed from the ceiling or from a low
level either from the floor or through an
outside wall depending on the
installation.
Note: Ensure the gas line has been
purged of any inline fragments before
connecting to the gas valve. This is
especially important where a new gas
service has been installed.
Warranty will be voided if the gas
valve is damaged with inline
fragments.
4.
Pipe entry to the product is
approximately 150mm above the datum
line. Leave around 250mm (Inbuilt) or
350mm (Console) of tail to make the
connection to the gas valve.
5. A gas cock is not required for domestic
application. However for commercial
applications the installer must supply and
fit an AGA approved ½” gas cock to suit
the gas specified.
E
LECTRICAL
1. Have a licensed Electrician install a 10
Amp 3 pin GPO (general-purpose
outlet).
Note: Ensure the polarity of the
outlet is correct otherwise the flame
can’t be sustained and the heater
won’t operate.
2. The GPO should be installed within
750mm of the left side or 350mm of the
right side of the heater.
3. Plug the pre-wired service lead into the
GPO once the installation is complete.
Note: Do not use an extension cord
to reach the GPO, as this is unsafe
.
Where required, have an Electrician
relocate the GPO.