Installation
BONAIRE WINDOW COOLER
Install ation
Installation Requirements
Tools
Drill (Power or Cordless)
Adjustable Wrench.
Phillips Head Screw Driver
Drills for drilling pilot holes into window
frame 1/8" (3.2mm) Drill
– or appropriate
for size of screw used.
¾” Philips Head Screws for affixing
window Infill Panel
Materials Required (Not supplied)
Silicone for sealing Window Infill panel
Length of 6mm (¼") copper or plastic
tubing
840mm (33”) of suitable spacer material
(if required)
Sillcock Valve - for water line connection
to facuet (see pg. 11)
Unpacking The Unit
Warning
When you receive your unit the fan assembly
and the over flow fitting will be partially located
inside the wet section of the product
.
Fan Assembly
Before installing the product in the window the
telescopic section of the unit
MUST
be fixed in place.
Step 1
Pull the fan assembly out of the unit by
approxi
mately 6” (150mm) until it hits the wet
box wall.
Step 2
Fix the fan assembly into place using the 12 Hi-
Lo hex screws supplied. Ensure the screws are
done up tight so there is no vibration between
the fan housing and the wet box.
Overflow Fitting
Step 3
Remove the tape covering the bottom of the
water over flow fitting assembly.
Step 4
Tighten the nut on the bottom of the overflow
fitting assembly to ensure there is no leakage
from the unit. Do not over tighten as it is
possible to strip the thread.
The unit is now ready for installing into your window.
Step 1
Step 2