background image

 

17 

 

9.  Technical Drawing 

 
 

 

 
 
 

 

 

 
 
 

 
 
 
 

 

 
 

 

Summary of Contents for OptiSpread 100 Battery

Page 1: ...Operating Instructions Bona OptiSpread 100 Battery Valid as of October 2014 ...

Page 2: ... 7 4 1 Device Safety 7 4 2 General Safety Notes 7 4 3 Safety Notes for handling battery operated Tools 8 5 Scope of Delivery and Operation 9 5 1 Scope of Delivery 9 5 2 Operation 10 5 2 1 Charging the Battery 10 5 2 2 Filling Replacing Tubular Bag 11 5 2 3 Applying adhesive 12 5 2 4 Replacing the Nozzle 13 5 2 5 Undersurface Quality 13 6 Maintenance and Cleaning 14 6 1 Maintenance 14 6 2 Cleaning ...

Page 3: ... separate compressor is no longer required By using the two batteries enclosed you can now execute your work on site without delay Please read these Operating Instructions carefully and thoroughly before using your new Bona OptiSpread100 Battery for the first time to ensure ideal safe use Please keep these operating instructions in a safe place ideally together with the purchase receipt We hope yo...

Page 4: ...iSpread 100 Battery The following harmonized norms have been applied EN 61310 2 1995 Safety of Machines Displays Labeling and Operating Part 2 Requirements concerning Labels IEC 1310 2 1995 EN 61310 3 1999 Safety of Machines Displays Labeling and Operating Part 3 Requirements concerning the organization and operation of Control Units actuators IEC 61310 3 1999 EN 614 2 2000 Safety of Machines Ergo...

Page 5: ...operational wear and tear e g adhesive nozzles Incorrect cleaning of components Our warranty does not cover devices whose serial number has been falsified changed or removed The warranty claim expires if components which have not been approved by Bona GmbH are installed into the device Claims exceeding free rectification of faults and errors e g claims for damages are not included in the scope of ...

Page 6: ...ensure you are familiar with the Bona OptiSpread 100 Battery and will be able to use the tool efficiently The operating instructions must be kept for the entire service life of the Bona OptiSpread 100 Battery and passed on to subsequent owners and users Working instructions Some parts of these operating instructions comply with working instructions This especially applies to instructions concernin...

Page 7: ...sive is pressed simply and evenly out of the adhesive nozzle via the ElektraFlow drive The amount of adhesive applied can be adjusted individually for each work process via the various toothing the speed of application and or the feed rate 3 2 Technical Data Bona OptiSpread 100 Battery Length 1378 mm toothed rack retracted 2398 mm toothed rack extended Weight empty 12 Kg filled approx 20 Kg Inside...

Page 8: ...imes The Bona OptiSpread 100 Battery must only be used by specialists or specifically trained staff If it is used by unqualified staff this may result in serious operating errors and personal injury Keep the device out of reach of children and ensure prevention of unauthorized use Never leave the operative or used device unsupervised Do not allow any children near to the device It is forbidden for...

Page 9: ...y the adhesive to the respective work positions Avoid contact to sensitive and finished surfaces 4 3 Safety Notes for handling battery operated Tools Power tools must NOT be exposed to rain or wetness There is increased risk of electrocution if water penetrates into an electrical device Keep your power tools in a safe place Unused power tools and battery packs should be stored in a dry elevated or...

Page 10: ... to your respective Bona system consultant or contact our Service Hotline on 49 0 180 42 66 283 Scope of Delivery Bona OptiSpread 100 Battery Quantity Part 1 Bona OptiSpread 100 Battery 1 Battery charger mains connection 2 14 4 NiMH battery packs 3 Nozzles 1250 G optional 1500 G 1 Nozzle head 1 Support block 1 Hook wrench 1 Transport bag We recommend the use of pincers to open the tubular bag Thes...

Page 11: ...it 30 minutes before trying to charge the battery again Note If the charger does not charge the battery under normal conditions please contact the Bona Service number provided Note When being charged the first time batteries do not charge up completely Several cycles are required to achieve complete charging The battery must only be charged using the charger provided Make sure the power supply is ...

Page 12: ...TIONS 1 Twist off the nozzle head fastened to the filler tube with a lock nut and place to one side 2 Remove the empty tubular bag 3 Unlock the toothed rack and pull out completely using the hook grip 4 Insert a new tubular bag horizontally and remove the clip Make sure the bag does not bend when you insert it 5 Screw the nozzle head back on release the clamping rubber and remove the machine from ...

Page 13: ...horizontally If work is interrupted for a longer period the partially used bag should be removed and closed using a cable tie When required this closed bag can then be used again Depending on the age of the foil bag gas pressure may develop inside the bag which results in a swelling of the foil This may make insertion more difficult We recommend that the foil be pricked with a needle close to the ...

Page 14: ...e inside of the nozzle base this must be removed manually 4 Liquid adhesive need not be removed 5 2 5 Undersurface Quality To ensure ideal application and functioning of the adhesive the undersurface must be ready for use and comply with the requirements of DIN 18356 If necessary appropriate action must be taken to prepare the undersurface to ensure it is suitable for use Respective Bona products ...

Page 15: ...f the Bona OptiSpread 100 Battery and les cleaning required when you have completed your work 6 3 Cleaning the Adhesive Nozzle The adhesive nozzle is designed as a non return nozzle which can be disposed of after you have completed your respective project However the nozzle can also be used repeatedly No specific range can be specified since the nozzle has a long service life on account of the har...

Page 16: ...hours without risk of drying In the case of longer storage 24 hours the nozzle must be removed from the tube If a foil bag is still in the machine it must be pressed empty or removed The adhesive nozzle is designed as a non return nozzle and can be disposed of on completion of the respective project If required the nozzle can be used repeatedly Avoid lengthy storage in damp or continuously wet and...

Page 17: ...urces of such errors Battery Is the battery fully charged Partially charged batteries may lead to automatic shut down of the feed due to incorrect identification of a malfunction Always charge the battery completely This also prevents a memory effect Toothed rack Is it bent or damaged Never put the device down on the rack Residual adhesive Is there any residual hardened adhesive in the machine noz...

Page 18: ...17 9 Technical Drawing ...

Page 19: ...company ARNOLD GmbH Co KG Post Box 1220 35772 Weilburg 49 6471 93940 If you have any questions ideas or unexpected complaints please contact your Bona system consultant Please explain your issue in detail to him her and provide the serial number which is on the lid of the Bona OptiSpread 100 Battery and the purchase date ...

Page 20: ...19 11 Disposal Adhesive guns batteries and chargers must be disposed of in compliance with the respective regulations of your local waste management company ...

Reviews: