![Bona MiniEdge Manual Download Page 13](http://html.mh-extra.com/html/bona/miniedge/miniedge_manual_2786413013.webp)
Bona MiniEdge
Carbon brushes (Pict. 20-22)
20 21 19
22
The task of the carbon brushes is to transport the power to the armature via the rotating collector. There
are two carbon brushes. They should be checked regularly and changed in pairs after approx. 100 hours
normal operating time.
N.B.
Carbon brushes wear more quickly when subjected to high loads.
Exchange:
Unplug the machine. Remove the plastic covers from the machine front cover. Unscrew the two black coal
covers on the machine housing. Pull out the carbon brushes. Check that the carbon brushes slides easily
from their position. If necessary replace them. When reassembling, check that the springs are correctly
placed in their positions.
N.B.
Don’t over tighten the carbon brush covers! Start the machine for testing.
Lamp exchange (Pict. 23-24)
23
Unplug the machine. Remove the screw fixing the rubber seal and pull out
the glass together with the seal using a screwdriver.
Change the lamp after you have loosened the four screws and carefully
lifted the machine cap. Check that the lamp is fixed between the springs in
the lamp socket. Attach the glass and the rubber sealing by pressing thr
rubber hooks with a screwdriver.
24
N.B.
Always use gloves or a rag when you hold the lamp. Never place your
fingers directly on to the lamp.
Assemble in the reverse order.
13