background image

LMM1214353_002    

A    

A    

B    

B    

C    

2    

1    

Aircraft with two oxygen    

cylinders have two overboard    
discharge indicators.    

NOTE    

CL−604 AIRCRAFT MAINTENANCE MANUAL − PART II

Servicing of the Oxygen System − Servicing

Figure 302

EFFECTIVITY:   ALL

12−14−35

Page 307

Mar 13/2009

Summary of Contents for CHALLENGER 604

Page 1: ...ine the pressure gauge 1 Make note of the value shown on the pressure gauge 1 2 Examine the overboard discharge indicator 2 Make sure that the green disc on the indicator 2 is not broken If the green...

Page 2: ...si 10 549 kPa 20 F 29 C 1435 psi 9894 kPa 40 F 40 C 1340 psi 9239 kPa d If the crew oxygen system is not fully pressurized do the servicing of the crew oxygen system TASK 12 14 35 614 801 4 Remove the...

Page 3: ...ircraft with two oxygen cylinders have two overboard discharge indicators NOTE CL 604 AIRCRAFT MAINTENANCE MANUAL PART II Quantity Check of the Crew Oxygen System Servicing Figure 301 EFFECTIVITY ALL...

Page 4: ...u use the correct equipment configuration C Consumable Materials REFERENCE DESIGNATION MANUFACTURERS REFERENCE AND OR SPECIFICATION 05 038 Oxygen Aviator s Breathing Gas MIL O 27210 Type 1 D Job Set U...

Page 5: ...OIL OR SOLVENTS THEY CAN START TO BURN 1 Do the servicing of the oxygen system as follows a Use an oxygen mask and set the regulator valve to N b Remove the dust cap 3 from the oxygen filler valve 4 c...

Page 6: ...at the oxygen filler valve 4 to release the pressure out of the filler line h When the pressure is released from the filler line disconnect the filler line from the oxygen filler valve 4 i Install th...

Page 7: ...2 1 Aircraft with two oxygen cylinders have two overboard discharge indicators NOTE CL 604 AIRCRAFT MAINTENANCE MANUAL PART II Servicing of the Oxygen System Servicing Figure 302 EFFECTIVITY ALL 12 14...

Page 8: ......

Reviews: