25
on the compressor, where it will evaporate. Make
sure the water discharge opening does not get
clogged. A light formation of ice on the interior back
during operation is normal.
A permanently high power level can lead to increa-
sed ice formation. In this case, the appliance can be
defrosted manually
→ set a lower power level.
Changing the bulb
CAUTION:
Do NOT remove the cover of the interior light.
The LED light may be replaced / repaired in case of
failure / defect only by an authorized specialist.
Troubleshooting
Before you contact an authorized specialist
Problem
Cause / Action
Unit is not
working
properly or
at all
∙ Check the power supply / tempera-
ture setting / ambient temperature.
∙ Unblock the ventilation openings,
install the appliance freely.
Loading is
too warm
∙ Check the temperature setting /
ambient temperature. ∙ Open the
door only as long as necessary.
Loud noise
during op-
eration
∙ Check the appliance position.
∙ See the section
“Operating noise”.
Water on
the unit
bottom
∙ Check the temperature setting /
water discharge channel or opening.
Light does
not work
∙ Check the power supply.
∙ See
“Changing the bulb”.
NOTE:
If a problem persists after following the steps above,
contact your trader or an authorized technician.
Technical Data
Climate class SN/N/ST/T: this appliance is intended
to be used at ambient temperature ranging from
10°C to 43°C.
Electrical connection………………...…………………..
Power voltage: ……………….......220-240 V~ / 50 Hz
Rated power: ………………...........….……...…...80 W
Rated current: ………………..............…...……...0.6 A
Dimension H x W x D / Weight…..…...………………..
Appliance size: …….………....123.0 x 54.0 x 54.0 cm
Net weight: ……………………….……approx. 34.0 kg
For more information about the product, scan the QR
code on the supplied energy label and/or visit the
official website of the product data bank:
https://eprel.ec.europa.eu
The right to make technical and design modifications
during continuous product development remains
reserved.
This appliance has been tested according to all rele-
vant current CE guidelines, such as electromagnetic
compatibility and low voltage directives, and has
been constructed in accordance with the latest safety
regulations.