10.4 Engine faults
Fault
Possible cause
Remedy
Engine does
not start
Fuel tank empty
Refuel, bleed the fuel system
Fuel filter clogged, in winter
due to paraffin separation
Change the fuel filter, use
winter fuel
Fuel lines leaking
Check all line connections for
leaks and tighten the fittings,
bleed the fuel system
Battery not charged or not
connected
Tighten the terminal clamps
on the battery, check all cable
connections
Starter defective
Have examined by a spe-
cialist
Emergency stop push button
is locked
Unlock the emergency stop
switch
Moving parts overheating
because of a lack of lubrica-
tion
Check the engine oil level,
correct if necessary
Check the engine oil filter,
replace if necessary
Have the lubrication system
examined by a specialist
Poor starting
of engine or
engine works
irregularly
with poor
power
Battery power too low, ter-
minal clamps loose or oxi-
dized causing the starter to
turn too slowly
Check the battery charge
condition, clean the terminal
clamps, tighten and cover
them with acid-free grease
Fuel supply too low, fuel
system clogged by paraffin
separation during winter
Replacing the fuel filter
Check all line connections for
leaks and tighten the fittings,
bleed the fuel system
Use winter fuel in winter
Engine oil with wrong SAE
viscosity class
Change the engine oil
Air filter dirty
Clean, replace if necessary
Troubleshooting – Engine faults
BW 100 AD-5
203
Summary of Contents for BW 100 AD-5
Page 2: ...2 ...
Page 9: ...1 Introduction Introduction BW 100 AD 5 9 ...
Page 13: ...2 Technical data Technical data BW 100 AD 5 13 ...
Page 19: ...3 Concerning your safety Concerning your safety BW 100 AD 5 19 ...
Page 64: ...Concerning your safety Signage BW 100 AD 5 64 ...
Page 65: ...4 Indicators and control elements Indicators and control elements BW 100 AD 5 65 ...
Page 81: ...5 Checks prior to start up Checks prior to start up BW 100 AD 5 81 ...
Page 96: ...Checks prior to start up Checking the hydraulic oil filter BW 100 AD 5 96 ...
Page 97: ...6 Operation Operation BW 100 AD 5 97 ...
Page 122: ...1 Plug Y04 Operation Emergency procedures BW 100 AD 5 122 ...
Page 123: ...7 Loading transporting the machine Loading transporting the machine BW 100 AD 5 123 ...
Page 134: ...Loading transporting the machine After transport BW 100 AD 5 134 ...
Page 135: ...8 Maintenance Maintenance BW 100 AD 5 135 ...
Page 188: ...Maintenance As required BW 100 AD 5 188 ...
Page 189: ...9 Setting up refitting Setting up refitting BW 100 AD 5 189 ...
Page 197: ...10 Troubleshooting Troubleshooting BW 100 AD 5 197 ...
Page 208: ...Troubleshooting Trouble shooting ECONOMIZER BW 100 AD 5 208 ...
Page 209: ...11 Disposal Disposal BW 100 AD 5 209 ...
Page 211: ......