![Bolide BC2036-PTC User Manual Download Page 31](http://html.mh-extra.com/html/bolide/bc2036-ptc/bc2036-ptc_user-manual_2785165031.webp)
Corrected temperature
:
it is adopted to modify the temperature measurement
value
of the temperature measurement object.
Distance
:
set the distance between the thermal imager and the temperature
measurement target, to facilitate the accuracy of the temperature
measurement. When the distance is less than 10m, adopt the actual
distance (to the accuracy of 0.5m) as much as possible.
Humidity
:
set the relative humidity of the utilization environment of the thermal
imager.
Background temperature
:
This item is valid when it is set to "On". A fixed
temperature can be adopted as reference temperature.
4.6.4
Image Setting
Image Setting Menu
Press OK button to pop out the floating panel, press OK button to pop out the floating
panel, select "Setting" option to activate the main menu, select "Image Setting" item in
the setting menu, and press OK button to pop out the image setting menu. Users can
set Auto Enhance mode, infrared transparency, alarm setting, isothermal setting, fusion
of High and Low Temperatures. Press up and down direction buttons to switch items.
Press left and right direction buttons to set the item contents. ">" indicates sub-menu.
Press right button to enter.
Auto / manual / AutoEnhance:
meet the user's demand on richer color and more
26