5
3
STANDARD DELIVERY
Item
Q-ty, pcs.
Proxy-3A (Proxy-3M, Proxy-3MA) Proximity Card Reader
1
Data Sheet
1
Detachable terminal blocks
2
Woodscrews with wall plugs
2
Packing
1
4
DESIGN, MOUNTING, CONNECTING
4.1
Safety Precautions
Safety precautions while preparing the product for operation are as follows:
−
The design of the reader meets the requirements of electric and fire safety in line with
Russian Standards GOST 12.2.007.0-75 and GOST 12.1.004-91.
−
There are no potential hazard circuits within the reader.
−
The reader is designed to provide its fire safety while emergency operating and on violations
of operation rules in line with GOST 12.1.004-91.
−
Do shut off power from the reader before mounting, installing, or maintaining this one.
−
Mounting and maintenance of the reader shall be carried out by persons with the second or
higher electric safety qualification level.
4.2
Design
The view and mounting dimensions of the reader are shown in Appendix A.
4.3
Mounting the Reader
4.3.1 The layout for attaching the reader to a wall is given in Appendix A.
4.3.2 The reader is to be attached to the wall using the two wood screws provided.
4.3.3 When the reader is to be installed on a metal surface use a non-metallic filler of at least 2
cm thick.
4.3.4 The front sticker is recommended to be pasted at the end of commissioning.
4.4
Wiring the Reader
4.4.1 The diagrams for connecting external circuits to the reader are shown in Appendix B.
4.4.2 The reader is equipped with a detachable terminal block to which wires are to be
connected.
4.4.3 To provide reliable operation for the reader, it is necessary to:
−
Install the reader at a distance of at least 0.5 m from another reader (if present) and at least
1 m from an electromagnetic lock;
−
Take into account that the input power voltage range of the reader is 8 V to 15 V;
−
The reader and the device the reader is connected to (for example, S2000-4 or S2000-2) shall
be powered by the same 12 V dc power supply.
If, an addition, an electromagnetic lock is connected to the same power supply then power must
be supplied to the lock via a separate wire. It is highly recommended to power locks by a separate
power supply.
If the electromagnetic lock is not equipped with a built-in circuit to suppress high voltage pulses
appearing when power is switched then a diode in reverse mode must be connected in parallel with the lock coil
(the maximum forward current for the diode must be at least 1 A).