recommended to work in mode of G1 modulated and G2 continuous, where the modulated
heater will be supplied form different phase then lighting.
Max VM opening
– defines the maximum valve opening. When running the process it will
be impossible to select higher valve opening, reducing the possibility to select higher
capacity then the column can provide and frequent process destabilization at beginning
phase of collecting the heart.
Min VM opening
– means minimum opening. When running the process it will be
impossible to select lower opening. Also the controller itself will no go below this vale if the
opening correction option is active. Use a value at which the rate of collection is still
reasonable. Setting too low value or even total closing would cause the controller to
encounter a problem with transferring to tails when the close time principle is selected, or
would case unnecessarily long collection of the heart and energy consumption.