background image

XF-300 Series High Volume Fume extraction systems 

Bokar International         www.bokar.com, 

www.No-Stat.com

, www.ZeroCharge.net 

Page 10 of 11 

VIII.  OPTIONAL EQUIPMENT 

 

 

XF-A75ESD

 - 75 mm ESD Arm with Funnel  

 

XF-B75ESD

 - 75 mm ESD Arm with Bench Bracket and Funnel  

 

XF-C75ESD

 - 75 mm ESD Cowl  

 

XF-D75ESD

 - 75 mm ESD Down Draft Tray  

 

 

 

XF-C75ESD

 

 

XF-B75ESD

 

XF-A75ESD

 

XF-D75ESD

 

 

  Variable speed/flow control available  

 

FILTERS 

All Extraction Systems incorporate a progressive series of filters designed specifically to maximize life for 

both particulate and gas capture. 

 

Pre Filter 

The pre filter is designed solely to protect the life of the micro filter. 

For the majority of units, X-KAR use a pleated synthetic media 

with a separation of typically 95% of particulate down to 0.8 

microns. In cases where larger amounts of sub micron particulate 

are generated, a higher efficiency filter can be fitted or stand alone 

Bag filter can be installed to give greater life to the pre filter and 

ensure adequate protection to the main filter. 

 

 

Micro Filter 

The Micro Filters incorporate a series of bonded webbing between the pleats. This feature not only ensures 

even spacing between each pleat, but also alleviates the possibility of airflow vibration or collapse through 

pressure build up during gradual filter saturation. Each Micro filter is designed to withstand up to 6 times the 

maximum operating pressure for its designated unit. With filter efficiency of 99.997% down to 0.3 microns 

and 95% as small as 0.01 microns. 

Summary of Contents for XTRACTOR XF-300 Series

Page 1: ...XF 300 Series High Volume Fume Extraction Systems P N X DOC154 20 Oct 10 Rev B 650 Scranton Pocono Hwy Covington Twp PA 18444 USA Tel 570 842 2812 Fax 570 842 4290 E Mail bokar bomir com www bokar co...

Page 2: ...NG 7 V SET UP AND INSTALLATION 7 VI SYSTEM DESCRIPTION and APPLICATION 8 VII TECHNICAL SPECIFICATIONS 9 VIII OPTIONAL EQUIPMENT 10 I INTRODUCTION A cost effective unit capable of extracting fumes with...

Page 3: ...XF 300 Series High Volume Fume extraction systems Bokar International www bokar com www No Stat com www ZeroCharge net Page 3 of 11 FIG 2 VIEW OF XF 300 Base Dimension...

Page 4: ...f not closely followed may result in severe personnel injury or death Danger is not used for property damage unless personal injury risk is present PRECAUTIONS The following are general safety precaut...

Page 5: ...workplace should be monitored with appropriate and adequate measuring detection devices to assure compliance with all applicable Health and Safety regulations Flammable vapors and gases i e Isopropyl...

Page 6: ...RATION PACE FUME EXTRACTION SYSTEMS MUST NOT BE USED TO EXTRACT FUMES FROM THESE SUBSTANCES WARNING Use with inappropriate chemicals or substances failure to provide regular maintenance or other misus...

Page 7: ...ails of model number voltage date of purchase where purchased and what is missing Missing items must be reported within 7 days from the date of purchase WARNING When unpacking please be careful and re...

Page 8: ...d The pre filter is always on top and the blue side of the prefilter should be facing upward The direction of airflow is clearly marked on the filter cartridge Airflow is always in a downward directio...

Page 9: ...bs 25 kg 200 cfm 340m3 h Radial Blower 115 or 230 52 Hi Efficiency 95 0 3 micron HEPA GAS 99 997 0 3 microns XF A75ESD 75 mm Arm with funnel 950 mm in length funnel 160 mm in diameter The measurements...

Page 10: ...ty of units X KAR use a pleated synthetic media with a separation of typically 95 of particulate down to 0 8 microns In cases where larger amounts of sub micron particulate are generated a higher effi...

Page 11: ...ailable for more demanding or diverse applications All filters are produced in accordance with ISO9002 with micron filtration complying with BS3928 A certificate of conformity for each filter is avail...

Reviews: