Refer to the mounting diagram and proceed as follow:

1

. With the wall box mounted, use wire nuts to connect AC 

wiring. Install the AC receptacle in the top of the box using
two #8 x ½" sheet metal screws.

2. Bring all wiring into the wall box, including the speaker and

microphone wires, through knockouts in the backbox.

3. Before installing the front panel on the wall box, install the

lock.When doing so, make sure that the locking cam is 
down when in the locked position.

4. Mount the front panel and door assembly to the wall box 

with #8 x 

1

- ¼" sheet metal screws through the Tinnerman

clips on the box.

5. Remove the feet from the amplifier.

6. Install the amplifier mounting screws in the door, using the

feet to hold the screws in place.

7. Mount the amplifier to the front door.
8. Connect speaker and input wiring to the amplifier.
9. Plug the amplifier into the AC receptacle.

1

0. Check operation of amplifier.

11

. Raise the door to a level which allows the door stop to be

installed with two #6 by ¼" sheet metal screws.

1

2. Assure that the door lock operates correctly.

50 Spring Street, Ramsey, NJ 07446

Tel: 20

1

-934-8500  Fax: 20

1

-934-9832

E-mail: [email protected];Web: www.bogen.com

(4 REQUIRED)

WITH AMPLIFIER

ORIGINALLY SUPPLIED

FOOT WITH SCREW

DOOR STOP MOUNTED BEHIND FRONT PANEL
WITH FELT PAD ON FRONT SURFACE

NO. 6x1/4 SCREW USED
TO MOUNT DOOR STOP
(2 REQUIRED)

NO. 8x1-1/4 SCREWS

MOUNT FRONT

PANEL TO WALL BOX

(4 REQUIRED)

TINNERMAN CLIPS
MOUNTED ON SIDES
OF WALL BOX
(4 REQUIRED)

NO. 8x1-1/4 (8) SCREWS

MOUNT WALL BOX

DOWN IN LOCKED

POSITION

LOCK

RECEPTACLE BOX
MOUNTED WITH 2
NO.8x1/2 SCREWS

A.C. RECEPTACLE
   BOX

CONDUIT ENTRY ENCLOSED
BY RECEPTACLE BOX

WIRE NUT
CONNECTIONS

KNOCKOUTS

AMPLIFIER (SOLD SEPARATELY)