Refer to the mounting diagram and proceed as follow:
1
. With the wall box mounted, use wire nuts to connect AC
wiring. Install the AC receptacle in the top of the box using
two #8 x ½" sheet metal screws.
2. Bring all wiring into the wall box, including the speaker and
microphone wires, through knockouts in the backbox.
3. Before installing the front panel on the wall box, install the
lock.When doing so, make sure that the locking cam is
down when in the locked position.
4. Mount the front panel and door assembly to the wall box
with #8 x
1
- ¼" sheet metal screws through the Tinnerman
clips on the box.
5. Remove the feet from the amplifier.
6. Install the amplifier mounting screws in the door, using the
feet to hold the screws in place.
7. Mount the amplifier to the front door.
8. Connect speaker and input wiring to the amplifier.
9. Plug the amplifier into the AC receptacle.
1
0. Check operation of amplifier.
11
. Raise the door to a level which allows the door stop to be
installed with two #6 by ¼" sheet metal screws.
1
2. Assure that the door lock operates correctly.
50 Spring Street, Ramsey, NJ 07446
Tel: 20
1
-934-8500 Fax: 20
1
-934-9832
E-mail: [email protected];Web: www.bogen.com
(4 REQUIRED)
WITH AMPLIFIER
ORIGINALLY SUPPLIED
FOOT WITH SCREW
DOOR STOP MOUNTED BEHIND FRONT PANEL
WITH FELT PAD ON FRONT SURFACE
NO. 6x1/4 SCREW USED
TO MOUNT DOOR STOP
(2 REQUIRED)
NO. 8x1-1/4 SCREWS
MOUNT FRONT
PANEL TO WALL BOX
(4 REQUIRED)
TINNERMAN CLIPS
MOUNTED ON SIDES
OF WALL BOX
(4 REQUIRED)
NO. 8x1-1/4 (8) SCREWS
MOUNT WALL BOX
DOWN IN LOCKED
POSITION
LOCK
RECEPTACLE BOX
MOUNTED WITH 2
NO.8x1/2 SCREWS
A.C. RECEPTACLE
BOX
CONDUIT ENTRY ENCLOSED
BY RECEPTACLE BOX
WIRE NUT
CONNECTIONS
KNOCKOUTS
AMPLIFIER (SOLD SEPARATELY)
11
11
1
2
3
3
4
1
9
4
5
6
7
8