Notice

Every effort was made to ensure that the information in this manual
was complete and accurate at the time of printing. However, infor-
mation is subject to change.

Federal Communications Commission (FCC) Statement
(Part 68)

This equipment is component registered with the Federal Communi-
cations Commission (FCC) in accordance with Part 68 of its rules.
In compliance with the rules, be advised of the following:

Registered equipment may not be used with Coin Telephone Lines.
Equipment may be used with Party Lines in areas where state tariffs
permit such connections and when equipment is adaptable for such
service.

This equipment is registered as follows:
Registration Number - US: CD272Q-17147-KX-N
Ringer Equivalence - 0.0B

If trouble is experienced, the equipment should be disconnected from
the interface to determine if this equipment, or the telephone line, is
the trouble source. If the equipment is determined to be malfunction-
ing, it should not be reconnected until repairs are effected. 

Repairs to this equipment, other than routine repairs, can be made
only by the manufacturer or its authorized agents.

If the equipment causes harm to the telephone network, the local
telephone company may temporarily discontinue your service and,
if possible, notify you in advance. If advance notice is not practical,
you will be notified as soon as possible. You will be given the oppor-
tunity to correct the problem and informed of your right to file a
complaint with the FCC.

The local telephone company may make changes in its facilities,
operations, or procedures that could affect the proper functioning of your
equipment. If they do, you will be given adequate notice in writing to
allow you an opportunity to maintain uninterrupted telephone service.

Important Safety Information

Always follow these basic safety precautions when installing and
using the system:

1. Read and understand all instructions.

2. Follow all warnings and instructions marked on the product.

3. DO NOT block or cover the ventilation slots and openings. They

prevent the product from overheating. DO NOT place the product
in a separate enclosure or cabinet, unless proper ventilation is
provided.

4. Never spill liquid on the product or drop objects into the ventilation

slots and openings. Doing so may result in serious damage to the
components.

5. Repair or service must be performed by a factory authorized

repair facility.

6. The product is provided with a UL-CSA approved, 3-wire ground

type plug. This is a safety feature. DO NOT defeat the safety
purpose of the grounding type plug. DO NOT staple or otherwise
attach the AC power supply cord to building surfaces.

7. DO NOT use the product near water or in a wet or damp place

(such as a wet basement).

8. DO NOT use extension cords. The product must be installed

within 6 feet of a grounded outlet receptacle.

9. DO NOT install telephone wiring during a lightning storm.

10.DO NOT install telephone jacks in a wet location unless the jack

is specifically designed for wet locations.

11. Never touch uninsulated wires or terminals, unless the line has

been disconnected at the paging or controller interface.

12.Use caution when installing or modifying paging or control lines.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION: TO PREVENT THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE ANY FRONT/BACK
COVERS OR PANELS. NO USER-SERVICEABLE
PARTS INSIDE. 

REFER SERVICING TO QUALIFIED PERSONNEL.

The exclamation point within an equilat-
eral triangle is intended to alert the user
to the presence of important operating
and maintenance (servicing) instructions.

The lightning flash with an arrowhead
symbol, within an equilateral triangle, is
intended to alert the user to the presence
of uninsulated "dangerous voltage"
within the product's enclosure that may
be of sufficient magnitude to constitute
a risk of electric shock to persons.

Summary of Contents for TBA15

Page 1: ... 2012 Bogen Communications Inc All rights reserved 54 5870 01B 1207 TBA15 Paging Talk Back Amplifier Installation and Use Manual ...

Page 2: ...tions when installing and using the system 1 Read and understand all instructions 2 Follow all warnings and instructions marked on the product 3 DO NOT block or cover the ventilation slots and openings They prevent the product from overheating DO NOT place the product in a separate enclosure or cabinet unless proper ventilation is provided 4 Never spill liquid on the product or drop objects into t...

Page 3: ...o the screw heads at the keyhole slots and position the two bottom screws Complete the installation by tightening all screws securely For best support use self fastening hardware when mounting the unit to plasterboard or similar thin materials The unit weighs 7 pounds For Rack mounted installation install the unit facing into the rack A blank panel may be used to cover the exposed rear surface of ...

Page 4: ...nfigurations Remote Privacy Any remote speaker may be modified for privacy see Figure 2 When SW1 is open paging announcements from the telephone handset are received at the loudspeaker but the telephone operator cannot monitor the loudspeaker area Single Zone Talk Back with TAMB2 A single paging zone at the trunk or station level is configured using the Bogen Model TAMB2 Telephone Access Module No...

Page 5: ...ol counterclockwise until the switching again becomes stable At this point the unit is critically stable any noise on the telephone side will cause the unit to switch to the talk mode and any loud impulse type noise at the loudspeaker may cause the unit to switch to the talk back mode 5 With the person in the talk back zone speaking rotate the SWITCH SENS control counterclockwise so that the unit ...

Page 6: ... Z3A Z2B Z2A Z1A Z1B TBOB TBIB TBOA TBIA PIB POB POA PIA POB BMOB POA BMOA BMSB BMSA BMBB BMBA MT2 MTI NCB NOB CMB CMA NCA NOA NRR NRT NRC NRC EMI EM2 TB GS TB 24V 24V 24V TI T R T 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 VOL BGM VOL RING NIGHT VOL TONE O l STATION TRUNK PAGE OUT PT PR T R 24VDC 150mA TAMB2 TELEPHONE PAGING ACCESS MODULE ZONE PAGING MODULE G S NO C NC CONTACT...

Page 7: ...ttack Time Less than 5 ms 3 ms typ Switching Delay Time adjustable from 50 ms to greater than 0 5 sec Output Impedance 25V or 70V balanced line Loudspeaker to Telephone Frequency Response 1500 Hz to 20 kHz Distortion Less than 2 Signal to Noise Ratio 40 dB Output Level Processed to meet FCC Part 68 Circuit Overload Protection Push to Reset circuit breaker Safe Operating Area SOA and thermal protec...

Page 8: ...ESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposition whether based upon warranty contract tort or otherwise shall be limited to the price of the product IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDIN...