Bogen NYQUIST NQ-S1810WT-G2 Installation Manual Download Page 8

www.bogen-ip.com  •  www.bogenedu.com

The NQ-S1810WT-G2 is warranted to be free from defects in materials and workmanship for five (5) 

years from the date of sale to the original purchaser. Any part of the product covered by this warranty 

that, with normal installation and use, becomes defective (as confirmed by Bogen upon inspection) 

during the warranty period will be repaired or replaced by Bogen, at Bogen’s option, with new or refur-

bished product, provided the product is shipped insured and prepaid to: Bogen Factory Service Depart-

ment: 4570 Shelby Air Drive, Suite 11, Memphis, TN 38118, USA. Repaired or replacement product(s) 

will be returned to you freight prepaid. This warranty does not extend to any of our products that have 

been subjected to abuse, misuse, improper storage, neglect, accident, improper installation or have been 

modified or repaired or altered in any manner whatsoever, or where the serial number or date code has 

been removed or defaced.
THE FOREGOING LIMITED WARRANTY IS BOGEN’S SOLE AND EXCLUSIVE WARRANTY AND THE PUR-

CHASER’S SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, 

EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS 

FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT 

ALLOWABLE BY LAW. Bogen’s liability arising out of the manufacture, sale or supplying of products or 

their use or disposition, whether based upon warranty, contract, tort or otherwise, shall be limited to the 

price of the product. IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSE-

QUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, LOSS OF DATA OR LOSS 

OF USE DAMAGES) ARISING OUT OF THE MANUFACTURE, SALE OR SUPPLYING OF PRODUCTS, EVEN 

IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES. Some States do 

not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or 

exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have 

other rights which vary from State to State.
Products that are out of warranty will also be repaired by Bogen Factory Service Department -- same 

address as above or call 201-934-8500, at owner’s expense.  Returned products which do not qualify for 

warranty service, may be repaired or replaced at Bogen’s option with a previously repaired or refurbished 

items.   The parts and labor involved in these repairs are warranted for 90 days when repaired by the 

Bogen Factory Service Department.  All parts and labor charges as well as shipping charges will be at 

the owner’s expense.
All returns require a Return Authorization number.  For most efficient warranty or repair service, please 

include a description of the failure. 

 9/2019

Limited Warranty,  Exclusion of Certain Damages

Summary of Contents for NYQUIST NQ-S1810WT-G2

Page 1: ...740 00124 00B 2006 2020 Bogen Communications Inc Specifications are subject to change NQ S1810WT G2 Nyquist Gen 2 VoIP Wall Baffle Speaker Installation ...

Page 2: ...orm C SPDT type 2 amp dry contact relay for controlling over riding third party devices like AV sources The speaker also allows DHCP deployment for easy installation You can let your Nyquist server automatically discover and configure your speaker or you can manually configure it through the speaker s web based user interface web UI The web UI also allows easy updating of firmware and setting of p...

Page 3: ...speakers will project sound in opposing directions Figure 1 HALLWAY Wall baffle speakers work well with rooms and hallways that are 20 to 60 wide Layout starts at one end of the hallway or room The first speaker should be installed 10 from the end of the hallway or room The next speaker on that wall should be installed 20 from the first speak er Each additional speaker should be installed 20 apart...

Page 4: ...tions see Figures 3 6 Figure 2 Step 1 Select the mounting option from Figures 3 6 and use the appropriate hardware for gang box mount or wall mount Bogen provides the screws and the washers for mounting on a standard electrical gang box but when mounting directly to a wall or other surface you must supply the appropriate hardware for the specific wall surface construction type for example concrete...

Page 5: ...n Figure 7 NQ E7020 Digital Call Switch Figure 7 Step 3 If the CAN bus is to be used ensure the CAN_H and CAN_L use Cat 5 10 100 twisted pair cable Step 4 To connect a third party device to the dry contact relay output do one of the following a If the device is looking for a Normally Open contact connect the device using the NO and COM terminals b If the device is looking for a Normally Closed con...

Page 6: ...housing Then rotate the speaker baffle downward until the two bottom sections C D snap together NOTE Refer to the Nyquist Gen 2 VoIP Speakers Configuration Manual or the Nyquist System Administrator Manual for de tailed instructions on how to configure these speakers Using the Reset Button The Reset button Figure 10 allows you to either reboot the VoIP speak er or to reset the appliance s configur...

Page 7: ...can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communica tions Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Additional Accessories The Nyquist Gen 2 VoIP Wall Baffle Sp...

Page 8: ...AW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposition whether based upon warranty contract tort or otherwise shall be limited to the price of the product IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL INCIDENTAL OR CONSE QUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS LOSS OF DATA OR LOSS OF USE DAMAGES ARISING OUT OF THE MANUFAC...

Reviews: