background image

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

50 Spring Street, Ramsey NJ 07446, USA 

Te: 201-934-8500; Fax: 201-934-9832; www.bogen.com

 

 

 

 

 

 

 
 
 

  

BOMDMU

Messaging and Call Stacking System 

 
 
 
 

 

    

 

 
 
 
 
 

User's Manual 

 
 
 

 

© 2012 Bogen Communications, Inc. 

All rights reserved. Specifications subject to change without notice. 

54-2213-01A  1208

 

Summary of Contents for BOMDMU

Page 1: ...BOMDMU Messaging and Call Stacking System User s Manual 2012 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 2213 01A 1208 ...

Page 2: ...mounted CAUTION If any wiring from the system leaves the premises you must use proper electrical protectors Regulations FCC Part 15 Radio Frequency Interference The BOMDMU generates and uses radio frequency energy and if not installed and used in strict accordance with the manufacturer s instructions may cause interference to radio and television reception Unit complies with the limits for Class A...

Page 3: ...und Music Input Volume 7 2 2 10 Background Music Input Connector 8 2 2 11 Audio Output Mode Switch 8 2 2 12 Output Volume 8 2 2 13 System Audio Control Connector 8 2 2 14 Configuration Switches 9 2 2 15 Messaging Playback Auxiliary Interface 13 2 2 16 Paging Control and Status Auxiliary Interface 13 3 PAGE STACKING FEEDBACK ELIMINATION OPERATION 14 3 1 Page Recording 15 3 2 Record Activation Metho...

Page 4: ...verrides the stacking and messaging functions and provides immediate real time access to the paging system PRE RECORDED MESSAGES For security and general public address messaging a pre recorded messaging sub system has been included Access both Record and Play functions of up to 99 messages 8 minutes of audio from an extension on your host telephone system Ten 10 start contacts have also been prov...

Page 5: ...tones DIP selectable Pre Page Tone DIP selectable POWER Power Pack 12V DC 1 Amp UL and CSA MEMORY Type FLASH Page Stacking 4 minutes per page input channel Messaging 8 minutes MESSAGE CONTROL of messages 99 Record Control DTMF control from messaging input Play Control Triggered from DTMF on messaging input or start contacts 10 PAGE CONTROL Priority Control contact is offered on the Priority Input ...

Page 6: ... into which you can plug the power pack This outlet should NOT be controlled by a wall switch 3 Make cable connections from the BOMDMU to the PBX or audio source and the Paging system 4 Set DIP switches to the desired operation 5 Connect the power supply System OK LED should illuminate GREEN 6 Test unit operation 2 2 Hardware Description FRONT The BOMDMU is a standard 1RU 19 rack mount chassis The...

Page 7: ...cators are global indicators that indicate that a particular function is active on any or all of the inputs on the system System OK LED Green indicates unit is ON Flashing indicates an error condition contact the factory for more information should this occur Recording LED Red indicates that a recording session is active on any one of the paging inputs Playing LED Green indicates that the audio ou...

Page 8: ...connector 6 position All pages to be recorded are input to the device through these connectors 1 Abort stops and deletes the recording when connected to Ground Pin 5 2 Record input connect to Ground Pin 5 to activate Unit records for duration of closure 3 Audio ring return 4 Audio tip signal 5 System Ground power return 6 Not used 2 2 4 Port Configuration Switch Paging Channels 1 3 Priority Input ...

Page 9: ...s 24V DC talk battery Compatible with loop start trunk ports 2 2 7 Messaging Audio Control Input Input RJ12 style connector 6 position Operation of the messaging portion of the system is provided through this interface 1 Not used 2 Not used 3 Audio ring return 4 Audio tip signal 5 Not used 6 Not used 2 2 8 Messaging Mode Switch Analog Station LEFT Position Impedance 900 ohm voltage for ring trip 7...

Page 10: ...el 500 mW 8 ohm Use this for longer runs or if not enough level can be reached with the line level output 2 2 12 Output Volume Controls the audio output volume level delivered to the paging system It is shipped with 1 1 gain factory set Adjusting this input clockwise increases the level and counter clockwise rotation decreases the level of the device 2 2 13 System Audio Control Connector Output RJ...

Page 11: ...ivation Method The method with which the user will enter the record mode Not in use NOTE Record Input activation is always available regardless of switch settings A maintained contact closure on any channel s record input will start the recording process on that channel for the duration of the closure 3 Active Not Active DTMF Tone Stripping DTMF tones recorded at the beginning of an audio message ...

Page 12: ...10 11 ...

Page 13: ...ll abort that particular recording 2 tones 7 Enable Abort This would allow a caller to abort a page being recorded by pressing the button two times within one second The recording will immediately be aborted and the busy back tone sent to the input A single sign during the recording will not have any effect Disable 8 Auto Play Play Mode Allows for automatic playback of page after recording Manual ...

Page 14: ...message 1 when connected to ground 3 Play 2 Plays message 2 when connected to ground 4 Play 3 Plays message 3 when connected to ground 5 Play 4 Plays message 4 when connected to ground 6 Play 5 Plays message 5 when connected to ground 7 Play 6 Plays message 6 when connected to ground 8 Play 7 Plays message 7 when connected to ground 9 Play 8 Plays message 8 when connected to ground 10 Play 9 Plays...

Page 15: ...ording time Pages exceeding this will be aborted and a busy back tone is generated Recordings that reach the end of memory are considered incomplete These pages are aborted and a busy back tone is generated If the memory is filled and a new recording command is offered the BOMDMU will not go into record mode and a busy back tone will be output to tell the user that the system is not available The ...

Page 16: ...ing process for the duration of the page Valid for Analog Station and Loop Start modes Audio Sense Setup Switches 1 OFF 2 ON For record activation without a separate switch closure or loop current The BOMDMU will start recording when the audio sensor goes active and will stop when the audio sensor is inactive for three seconds Valid for Analog Station Loop Start and Dry Loop modes DTMF Activation ...

Page 17: ...AGING PRE RECORDED The BOMDMU offers a pre recorded messaging system for quick and easy access to standard or frequently used pages This system allows messages to be recorded and permanently stored in FLASH memory Playback is provided via DTMF command or contact closure The messaging portion of the BOMDMU can store up to 99 messages in 8 minutes of memory DTMF Commands Code Name Description End Us...

Page 18: ...audio interface for your zone controller amplifier or public address system All audio from the paging channels priority input messaging system and BGM input is routed to this output The BOMDMU manages stored pages on a first in first out basis This means that pages will be played in the order they were successfully completed and or triggered independent of the particular input Only the priority in...

Page 19: ...Appendix BOMDMU Connection to Override to PCMTIM BOMDMU Connection to Override to UTI1 1 2 18 ...

Page 20: ...ng c ing ck ges and nput ss s of vices U also e yed rd BOMDMU Connection to Override to UTI312 ...

Page 21: ...___ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ___________________________________________________...

Page 22: ...LOWABLE BY LAW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposition whether based upon warranty contract tort or otherwise shall be limited to the price of the product IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS LOSS OF DATA OR LOSS OF USE DAMAGES ARISING OUT OF ...

Page 23: ...50 Spring Street Ramsey NJ 07446 USA Te 201 934 8500 Fax 201 934 9832 www bogen com ...

Reviews: