DESCRIPTION

The Bogen Model AFDS2,Automatic Failure Detector and Substitutor, is an electronic unit which continuously supervises the
operation of the main and standby power amplifiers in a sound system. Should the main amplifier’s output level drop by as
little as 2 dB, the AFDS2 substitutes the standby power amplifier.The changeover is nearly instantaneous with virtually no loss
of signal.

The AFDS2 injects a set level of a supersonic frequency (40 kHz) into the inputs of the main and standby power amplifiers
and continuously samples their outputs. If the 40 kHz level from either amplifier should fall below 2 dB*, a fault alert tone
will sound, indicating a failure. Front panel-mounted LEDs indicate whether the main amplifier or the standby amplifier failed.
The fault alert tone may be silenced by momentarily pressing the Silence button; however, the LED will stay on for the dura-
tion of the malfunction.

The AFDS2 may be used in either 25V or 70V systems. Booster output may be balanced or unbalanced; but, in a balanced sys-
tem, two accessory input isolation transformers (Model TL

1

00) are required.

The AFDS2 input impedance from the audio source is 

1

0,000 ohms. In applications where the pre-amplifier is located away

from the amplifier, the AFDS2 input can be converted to 600 ohms with the accessory WMT

1

A Line-Matching Transformer.

Screwdriver-adjustable controls for setting the oscillator level and the detector sensitivities are provided on the rear panel.

The AFDS2 operates from a 

1

20V AC/60 Hz or 

1

2V DC source. Line power consumption is 

1

5W. All connections are made

at screw terminals and RCA connectors on the rear chassis.The unit has a standard 

1

9-inch wide panel, is 3 

1

/2-inches high

and is suitable for either rack or cabinet installation.

* Threshold is adjustable

PACKAGE CONTENTS

• Automatic Failure Detector & Substitutor unit 
• Installation and Use Manual

TECHNICAL SPECIFICATIONS

Supervision Frequency:

40 kHz

Supervision Frequency Level:

5mV to 50mV into 47k ohms

Input Impedance:

1

0k ohms

Detector Input Signal:

2V @ 40 kHz

Detector Supervision Range:

2 dB (min.) to 

1

2 db (max.)

Failure Indicators:

LEDs (visual) and tone module (aural)

Controls:

Screwdriver-adjustable controls for oscillator level and detector sensitivity

Remote Annunciation:

Status terminal provides 

1

2V DC/500mA in the failure mode

Operating Temperatures:

1

4°F to 

1

49°F (-

1

0°C to 65°C)

Power Consumption:

1

20V AC,

1

5W, or 

1

2V DC @ 0.5A

Dimensions:

1

9" W x 3 

1

/2" H x 7-

1

/2" D

Weight:

8 lb.

Accessories:

Two TL

1

00 transformers for 25V or 70V balanced systems;WMT

1

A Line-Matching Transformer to match

the input from a 600-ohm balanced line

EQUIPMENT CONNECTIONS

AC Power Connections:

The AC line cord has a three-prong plug which should be plugged into a three-wire 

grounded

1

20V, 60 Hz outlet.This will automatically ground the chassis.

Auxiliary DC Power Connections:

The unit may be powered from the 

1

2V DC supply. The positive lead must be con-

nected to the EXT PWR terminal on the chassis and the negative lead to the GND terminal.

Input Connections:

The input impedance of the AFDS2 is 

1

0,000 ohms, accepting any unbalanced input capable of supply-

ing a signal at least 

1

0% greater than that needed to drive the power amplifiers (which must have an input impedance  of

1

0,000 ohms or greater). Provisions are incorporated for mounting an accessory Model WMT

1

A transformer to match the

input from a 600-ohm balanced line.

System Connections:

Single-conductor, low capacity shielded wire should be used for all input connections. These leads

should be as short as possible. The remaining connections can be made with either double-conductor shielded wire or
#20AWG hookup wire.

Note:

Input cables should be routed separately from output cables.