BOGE FOCUS compressor control for piston compressors
Page 31
FOCUS
1.8
Data of external connections
Wire cross sections of
external connections
For external connections the following conductor cross sections are to be
used:
Screw terminals:
Tension spring terminals
Terminal
Cross section
Fixed / flexible min
0.2 mm²
Fixed / flexible max
2.5 mm²
Flexible with ferrule (with / without plastic sleeve) min
0.25 mm²
Flexible with ferrule (with / without plastic sleeve) max
2.5 mm²
AWG / kcmil min
24
AWG / kcmil max
12
2 conductors with identical cross section fixed min
0.2 mm²
2 conductors with identical cross section fixed max
1 mm²
2 conductors with identical cross section flexible min
0.2 mm²
2 conductors with identical cross section flexible max
1.5 mm²
2 conductors with identical cross section flexible w. AEH (ferrule)
without plastic sleeve min
0.25 mm²
2 conductors with identical cross section flexible w. AEH (ferrule)
without plastic sleeve max
1 mm²
2 conductors with identical cross section flexible w. TWIN ferrule
without plastic sleeve min
0.5 mm²
2 conductors with identical cross section flexible w. . TWIN ferrule
without plastic sleeve max
1.5 mm²
Terminal
Cross section
Capacity of terminal
0.5...1.5 mm²
Single wire
0.5...1.5 mm²
Stranded wire
0.5...1.5 mm²
With ferrule
0.5...1.5 mm²
AWG-conductor
26...14