background image

 

button ‘

▲’, the set temperature value is raised.  When all buttons are released, 

the actual chamber temperature is displayed. 
 
In the event of power loss, the Temperature Controller retains the last set 
temperature value. 

4.3 

Loading Carousel 

Warning!

  Sharp rotating parts.  Do not attempt to add or remove tubes until the 

motor has stopped.  The motor can be stopped by turning the power switch to the 
“Off” position or by depressing the “Pause” button located on the back of the unit, 
(see figure 2).  When loading the Carousel, it is recommended that the load be 
evenly distributed.  Tubes should be positioned with sufficient clearance from the 
chamber wall to avoid interference from the screw heads during tube rotation. 

4.4 

Spindle Adjustment 

If desired, it is possible to adjust the Spindle, which imparts a “rocking” or 3-D 

motion to get an additional washing action to the tube.  The Clips have been 
factory set to position the tubes horizontally, but this can be adjusted by 
loosening the screws securing the clips, rotating them slightly, then re-tightening 
the screws to get the desired effect.  

Warning!

  Remove power from the unit 

before adjusting. 

4.5 

Removing/Installing Carousel 

Warning!

  Remove power from the equipment before removing or installing the 

Carousel.  To remove Carousel, first remove all tubes. Position Carousel so the 
socket head screw on the shaft (located on the left side of the drive shaft) is 
accessible, and turn power off.  Loosen socket head screw with a 1/16 inch hex 
key and slide the carousel to the right. To install Carousel, reverse this 
procedure. 

4.6 

50ml Conical Centrifuge Tubes 

Be sure to use tubes that can handle the elevated temperatures used in 
hybridization.  We recommend that you contact your supplier or tube 
manufacturer.  In general, scientists have found that tubes made from 
polypropylene with polyethylene caps provide reliable performance.  Tubes made 
from polystyrene should be avoided. 
 
When inserting the centrifuge tube into the clamping mechanism, place the 
clamp toward the middle of the tube.  Pinching the tube near the cap may cause 
a leak. 

5.     Accessories 

5.1 

Multi-Tube Carousel 

Catalog Number 230332 

Summary of Contents for Bambino 230301

Page 1: ...Boekel Bambino Hybridization Oven Models 230301 and 230301 2 Operating Instructions N2400204 Rev 0 11 03...

Page 2: ...the temperature 3 4 3 Loading Carousel 4 4 4 Spindle Adjustment 4 4 5 Removing Installing Carousel 4 4 6 50ml Conical Centrifuge Tubes 4 5 Accessories 4 5 1 Multi Tube Carousel 4 5 2 Clips for Multi T...

Page 3: ...nding to that on the serial number label Connect only to a power supply that provides a safety ground terminal Before moving disconnect at the power supply socket Do not remove the plug Do not check t...

Page 4: ...the carrier Complete and return the Warranty Registration Card Packs should contain Hybridization Oven Power line cord Operating instructions 3 2 Installation Place the Oven on a flat and stable surfa...

Page 5: ...sening the screws securing the clips rotating them slightly then re tightening the screws to get the desired effect Warning Remove power from the unit before adjusting 4 5 Removing Installing Carousel...

Page 6: ...a Actual temperature is lower than set temperature a Check set temperature b Temperature control circuit fault b Have unit checked by competent person 4 No rotation LEDs illuminated a An obstruction p...

Page 7: ...30V 0 5AF Push the fuse drawer back in Reconnect unit to the power supply 9 Warranty When used in laboratory conditions and according to these operating instructions Boekel warrants this product to be...

Page 8: ...7 Drawer Fuse I Switch Power Knob Control Speed Button Pause Figure 2 Figure 1 Lamp Heater Display Temperature...

Reviews: