operating window, the parameters, mode and status of the machine can be adjusted from the

button in the screen. It is very easy to learn and operation.

6.6 Emergency Switch

Emergency switch connected with the general power supply, press the button, the

machine will be turned off. Before restarting the machine, should switch the key switch to
“OFF” , and adjust the emergency according to the mark position, then turn the key switch to
“ON”

6.7 Laser beam output warning

As long as there is laser output, the LCD screen will appears a light warning, the warning

light and the laser output completely synchronization.

ATTENTION

If you find out the warning light is in constant light, please press the emergency switch
immediately to turn off the machine.

6.8

Disinfection measures

As the hand piece needs to contact with, please disinfection more than 10 minutes by

alcohol or iodine before use it.

7. Specifications

Laser type

Diode Laser

Wavelength

808 nm

Max. Input Power

3200 W

AC Power Supply

110V±10%, 220V±10%, 50~60 Hz

Big Spot Size

22*35 mm

Laser Power

1500 W

Pulse Width

15~100 ms, adjustable

Energy

0~37 J/cm

2

, adjustable

Frequency

1~5 Hz, adjustable

Small Spot Size

12*10 mm

Summary of Contents for KES-DV2400

Page 1: ...1 808nm Diode Laser Operation Manual KES145 ...

Page 2: ...etrate the skin to hair follicles according to selective absorption principle laser energy is absorbed by the black pigment then make hair loss regeneration ability during the treatment the unique sapphire cooling system can effectively protect epidermis is not burned to achieve painless fast permanent hair removal This product uses a warm pulse and heating pulse constitute a hair removal irradiat...

Page 3: ...s Science technology development co Ltd In the manual the contents of the black body part should be paid special attention 1 1 Copyright The appearance of the product laser micro study coupling technology control software and other related part is part of the Beijing KIERS Science and Technology Development Co Ltd intellectual property protected by patent or copyright protection any unit or indivi...

Page 4: ...ing damaged and check if all accessories are inside and please keep all packaging materials They are needed when you need to deliver the machine 3 3 Request for the working room In addition to the warning signs when working with 4 type s lasers the working room should be set up with a laser work warning 3 3 1 Entrance Notice There should be strict mark at each entrance There should be laser safety...

Page 5: ...ation 808nm laser hair removal machine is related to types 4 of laser products Type 4 laser is high energy laser should be used carefully to avoid dangerous Prohibited to get close to any Inflammable Materials 4 2 Eye Protection Dangerous No direct observation of the laser beam or reflection scattering out of the beam Otherwise it will cause damage to the retina Nominal ocular hazard distance NOHD...

Page 6: ...intermittent process adjust the machine to Standby under this condition the pedal switch can t be used 4 5 Prevent the scattering of laser beams Avoid laser beam focused on flammable material otherwise it will cause combustion The hand piece should be placed in working area and only can be controlled by the operator forbidden to be operated by any third person 4 6 Manual recovery Under any abnorma...

Page 7: ...machine before every treatment The following person or area is prohibitive to use the machine Cancer especially skin cancer Pregnant including IVF Using Photosensitivity drugs and Chinese traditional medicine Sensitive to 808nm laser Took sunshine 3 4 weeks before treatment there is inflammation or herpes simplex infection Scar history of tumor diabetes mellitus Dry and sensitive skin endocrine dy...

Page 8: ...s the dynamic electrocardiogram 6 Product description 6 1 Brief introduction Main parts for KES DV2400 DV600 Control system for 808nm diode laser Temperature control system for cooling Laser hand piece Water Cooling system Safety protection system 6 2 Main body Main laser system includes 808nm diode laser bars sapphire crystal and temperature controlling system Circuit control system water cooling...

Page 9: ...e three buttons turned at the same time There are two keys for one machine the keys should be kept by professional users 6 4 Laser output ATTENTION There is a sapphire crystal in the output window forbidden to be blocked by any objectives 6 5 Touch screen This machine uses 10 inches of high sensitivity high resolution touch LCD screen as the ...

Page 10: ...s laser output the LCD screen will appears a light warning the warning light and the laser output completely synchronization ATTENTION If you find out the warning light is in constant light please press the emergency switch immediately to turn off the machine 6 8 Disinfection measures As the hand piece needs to contact with please disinfection more than 10 minutes by alcohol or iodine before use i...

Page 11: ...efore connecting the outlet make sure the technical data of the power meet the requirements or it may cause damage to the equipment or even cause bodily injury 1 When using the machine must maintain good ventilation environment there is no barrier around the machine and keep at least 30CM distance from the wall for ventilation cooling 2 Connect the plug of the hand piece with the socket of the mac...

Page 12: ...nel Notice Don t fill the water quickly to prevent the water spill over 3 When filling the deionized cooling water please notice the change of the water level When the water spill over from the water level window please stop filling and take off the water pipe clean the residual water 4 Notice when using the machine at first time there is no water in the water pump refrigerator and the water route...

Page 13: ...et press Ready button 8 3 1 Check the machine working status and interface presentation After entering the work interface then check if the status of the device is normal and check if there is warning Initial working interface and the warnings There is no warning sign with the condition of normal status Water Level Warning when the water level is lower than the predetermined level So the water sho...

Page 14: ...terlock alarm it will warn when the interlock is open or don t connect the gate interlock Laser light warning it will alarm when the laser is lighting Notice after the exclusion of all the alarm information to the normal operation of the laser 8 4 Operation 8 4 1 Preparation before use 1 Before using the equipment must check the installation of the equipment to meet the requirements of the device ...

Page 15: ...ments of the equipment enter the initial work interface according to the actual need to choose the appropriate mode of operation Enter the hair removal operation interface 2 Hair removal screen operation 1 Normal Mode Key description Ready the energy output is controlled by two levels that is the Ready button press and hold the key to the hand to have the energy output Standby after clicking on th...

Page 16: ...se maintain communication with patients according to patients feeling to adjust parameters at any time Note once the patient s skin mild burns must immediately stop operating and in time to carry out the necessary treatment to prevent wound infection 5 Before the operation the headpiece must be disinfected can use 75 medical alcohol to wipe then dry prohibited the use of sharp scratch head surface...

Page 17: ...al Step 1 cleaning Before hair removal need to clean the area where the hair will be removed the area for disinfection treatment Step 2 shaving hair In order to carry out the hair removal the laser can better conduction The surface of the hair need to be shaved ...

Page 18: ... process of hair removal is not suitable for the lowest before hair removal smear gel evenly to the area of hair removal Step 4 Setting Parameters The energy output frequency output and laser output can be adjustable to achieve the best user experience For reference as below ...

Page 19: ...ence of equipment fault or line 1 Plug in the power plug 2 Replacement insurance 3 Please professional worker check Power insurance specification is 16A Equipment alarm information can not work 1 not filled with DI water cooling water 2 Equipment failure 1 filling with deionized water 2 Please professional worker check Equipment with water temperature water level water function please pay attentio...

Page 20: ...e from low energy to high energy gradually the patients must feel comfortable avoid energy is too high otherwise it may lead to damage the skin If the skin damage need to immediately stop the current operation and timely disposal of the necessary 3 The equipment has the function of fault alarm when the equipment alarm must immediately stop the current operation check the cause of the failure as so...

Page 21: ...therwise it may cause damage to the equipment and even lead to personal injury 5 when the breakdown of the equipment please examine the machine according to the table if the fault cannot be eliminated contact our after sales service in time professional maintenance staff is strictly prohibited without permission open the equipment otherwise not warranty 6 Environmental protection and others Materi...

Page 22: ...ments installation use storage it must be in strict accordance with the relevant requirements of the installation use storage or our company does not stand any responsibility 4 If the fault can t be excluded please contact with our service personnel disassembling the machine without our company service s permission is prohibited otherwise no warranty or stopping warranty our company does not under...