3.2.1.

 

Factory set programmes 

The programmes 1-3 are pre-set by the factory, and work for the most common uses. 
These programmes can by changed as well. 

Programme 

Nr 

t1 

Temp 1 

t2 

Temp 2 

t3 

Temp 3 

t4 

Temp 4 

t5 

Temp 5 

Drying 

5:00 h 

150 °C 

3:00 h 

150 °C 

 

 

 

 

 

 

Onglaze fire 

6:40 h 

450 °C 

0 min 

750°C 

15 min 

750°C 

 

 

 

 

Once-fire 
980°C 

9:00 h 

720 °C 

0 min 

980°C 

20 min 

980°C 

 

 

 

 

Glaze firing 
1020°C 

6:00 h 

650°C 

0 min 

1020°C 

20 min 

1020°C 

 

 

 

 

Glaze firing 
1280°C  

6:00 h 

650°C 

0 min 

1260°C* 

20 min 

1260°C* 

 

 

 

 

 
Once-fire 

5:00 h 

150 °C 

3:00 h 

150 °C 

4:30 h 

650°C 

0 min 

980°C 

20 min 

980°C 

*With the programmed final temperature of 1260°C and retention time of 20 minutes 1280°C 
can be reached. 

 

3.3.

 

Changing the programmes 

To change the controller’s programmes, first choose a programme as described earlier in 
chapter 3.2. 

Entering the time segments 

Push the    button once. The LED 

t1 

will start blinking. You are now in the altering mode for 

“time”. You can now change the value that is displayed using the keypad. Use the buttons   
and    to move back and forth through the time segments scale.  

Entering the temperatures 

Push the    button once. The first temperature LED will start blinking. You are now in the 
altering mode for “temperature”. You can now change the value that is displayed using the 
keypad. Use the buttons   and    to move back and forth through the temperature segments 
scale.  

 

Summary of Contents for SE 9-6

Page 1: ...troller SE 9 6 1 Introduction 2 2 The first start 2 3 Working with the SE 9 6 3 3 1 Control elements on displays 3 3 2 Choosing and starting saved programmes 4 3 2 1 Factory set programmes 5 3 3 Changing the programmes 5 3 3 1 Meaning of the LED s 7 4 The firing process 7 5 Error messages 8 6 Technical Data 9 6 1 Data 9 6 2 Connecting of the controller 9 ...

Page 2: ...en started Important note Do not put the controller on the top of the furnace during the firing process Do not alter the length of the cable connecting the controller to the furnace in any way All of our controllers are checked and tested intensively in our company But if there is a malfunction please try to find out the problem using chapter 5 of this manual If the problem cannot be solved this w...

Page 3: ...Bodmer Ton AG Holzrüti 1 CH 8840 Einsiedeln Phone 41 55 418 28 58 E Mail info bodmer ton ch Website www bodmer ton ch 3 3 Working with the SE 9 6 3 1 Control elements on displays ...

Page 4: ...hey are individually altered and saved Starting a saved programme Push the button to call up the programme mode The display will show P Use the keypad to choose your desired programme Then push the button to start firing using the previously chosen programme For example To choose and start programme number 3 push the following button If you push the button again the programme will be stopped ...

Page 5: ... C 3 00 h 150 C 4 30 h 650 C 0 min 980 C 20 min 980 C With the programmed final temperature of 1260 C and retention time of 20 minutes 1280 C can be reached 3 3 Changing the programmes To change the controller s programmes first choose a programme as described earlier in chapter 3 2 Entering the time segments Push the button once The LED t1 will start blinking You are now in the altering mode for ...

Page 6: ...data to zero by choosing the programme number see chapter 3 2 This is useful if you want to set up a completely new program Note Saved programmes will not be affected by this Saving a program You can save up to nine programmes for your most common uses To save a programme follow these instructions First set up a programme as you wish Then push the button twice The display will now show S Now enter...

Page 7: ...hows that the firing process has been finished and the heating has been switched off The furnace will now cool off The LED s above the time LED s show the currently set temperature of the segment 4 The firing process After choosing a program see chapter 3 1 and pressing the button the firing process will be started In case that you have entered a delay time the delay time will be displayed and cou...

Page 8: ...2 This error massage will be shown whenever the furnace heats for more than 18 hours with maximum power Heating elements are too old or defective On a 3 phase system one phase missing check house fuse F3 lf the measured temperature is too high F3 will be displayed Thermocouple defective Wiring of the thermocouple defective F4 lf the measured temperature has a negative value F will be displayed The...

Page 9: ...e Consumption 2 VA Output 2 Contacts 230V max 4 A Input Thermoelement Typ S Pt10Rh Pt Accurate 1 C Resolution 0 3 1 Digit Measures 200 100 45 mm Weight 0 6 kg Ambient temperature 0 to 50 C 6 2 Connecting of the controller Wire Nr Harting 7D Pin Nr Name red orange white white 3 4 Wire of thermocouple Type S 1 5 Input L1 2 2 Input N 3 6 Output Heating Relay 4 1 Output N 7 7 Output Safety Relay ...

Page 10: ...Bodmer Ton AG Holzrüti 1 CH 8840 Einsiedeln Phone 41 55 418 28 58 E Mail info bodmer ton ch Website www bodmer ton ch 10 ...