background image

SAVE THESE INSTRUCTIONS

THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY.  

THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

Bodine © 2018 Signify Holding. All rights reserved.  

236 Mt. Pleasant Rd. • Collierville, TN USA 38017-2752 • Tech Support 888-263-4638 • Fax 901-853-5009 • www.bodine.com

442294629632

BSL310LPST

03/07/19

Ni - Cd

CLASS 2 OUTPUT

Self-Testing Emergency LED Driver

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

! IMPORTANT SAFEGUARDS !

WHEN USING ELECTRICAL EQUIPMENT, BASIC

SAFETY PRECAUTIONS SHOULD ALWAYS BE 

FOLLOWED, INCLUDING THE FOLLOWING:

  1.  To prevent voltage from being present on yellow & yellow/black output leads prior to installation, converter 
    connector must be open. Do not join converter connector until installation is complete and AC power is  
    supplied to the emergency driver.
  2.  This product is for use with an emergency LED lighting load and supplies nominaly 10.0 W of power, with 
    a voltage of 15-52 VDC in emergency mode for a minimum of  
    90 minutes, in compliance with NFPA-101 and NEC 700.12. 

 

  3.  Make sure all connections are in accordance with the National Electrical Code or Canadian Electrical Code and   
    any local regulations.
  4.  To reduce the risk of electric shock, disconnect both normal and emergency power supplies and converter  
    connector of the emergency driver before servicing.
 5. This emergency driver is suitable for both factory or field installation. For field installation, please see the  
    instructions on page 2. 

 

6.  This product is suitable for use in damp locations where the ambient temperature is 0ºC minimum, +55ºC  

    maximum. Product is also suitable for installation in sealed and gasketed fixtures. Product is not suitable  

 

    for heated air outlets and wet or hazardous locations. Maximum allowable case temp is 65ºC. See Page 4  
    for Tcase measurement location.
  7.  An unswitched AC power source is required (120-277 VAC, 50/60 Hz).
  8.  Do not install near gas or electric heaters.
  9.  Do not attempt to service the battery. A sealed, no-maintenance battery is used that is not field 
    replaceable. Contact the manufacturer for information on service.
 10.  The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
 11.  Do not use this product for other than intended use.
 12.  Servicing should be performed by qualified service personnel.
 13.  Equipment should be mounted in locations and at heights where it will not be subjected to tampering by  

 

    unauthorized personnel.
 14.  For Canadian application the output terminals should be in compliance with the accessibility requirement of  
    the Canadian Electric Code.
15.   This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) 
    this device may not cause harmful interference, and (2) this device must accept any interference that may    
    cause undesired operation.
16.  This product must be grounded. See the wiring diagrams for details.

Installation Instructions

Summary of Contents for BSL310LPST

Page 1: ...e for both factory or field installation For field installation please see the instructions on page 2 6 This product is suitable for use in damp locations where the ambient temperature is 0ºC minimum 55ºC maximum Product is also suitable for installation in sealed and gasketed fixtures Product is not suitable for heated air outlets and wet or hazardous locations Maximum allowable case temp is 65ºC...

Page 2: ...e forward voltage of the luminaire s LED array is within the limits of this emergency LED driver The forward voltage of the LED array is commonly designated as Vf and should be found on the luminaire markings in the luminaire specifications or imprinted directly on the LED arrays If multiple LED arrays are to be driven verify that the total forward voltage is within the limits of this product Usin...

Page 3: ...ube is too long cut the plastic tubing to necessary length After cutting the tube to the proper length assemble the 2W ITS To assemble the 2W ITS Assembly Feed the 2W ITS leads through the plastic tubing Insert the white bushing in the opposite end of tube from the 2W ITS body Pull switch leads and use provided tie wrap to secure leads snug against white bushing Unscrew hex nut to apply tension to...

Page 4: ...ondition has not been corrected by the next scheduled test the unit will once again detect the failure and signal the failure indicator To perform a manual self diagnostic test push and hold 2 wire ITS for minimum of 5 seconds Once 2 wire ITS is released the emergency driver will perform a 5 second diagnostic test During this test unit will monitor the operation of the LED load battery voltage and...

Page 5: ... be charged for at least 24 hours before conducting a long term test NOTE 2 The YELLOW YEL BLK VIOLET BROWN RED and WHITE CONVERTER CONNECTOR wires are all Class 2 Tc 222 25 mm 15 mm TCASE TEST POINT LOCATION AC LED DRIVER WALL SWITCH UNSWITCHED HOT YELLOW COMMON WHITE YEL BLK OUTPUT LED LOAD LED LOAD WHITE WHT BLK WHT RED BLUE OUTPUT BLACK BLACK WHITE GREEN GROUND L E D D R I V E R E M E R G E N ...

Reviews: