![Bodet Style 10 Date Installation And Operation Manual Download Page 32](http://html1.mh-extra.com/html/bodet/style-10-date/style-10-date_installation-and-operation-manual_2782372032.webp)
32
AFNOR synchronisation
EN
+
S
S
S
S
S
S
S
S
S
Hold down for 3 seconds
+
+
S
Hold down for 7 seconds
+
Open configuration menu
Software version
May differ from the version shown depending on the date of purchase.
Select synchronisation mode
AFn: AFNOR (default)
AFnI: Independent AFNOR (the clock operates using its internal time base)
IrIG: IRIG-B
Resetting the clock (enabled if “rstY” is selected)
Restore to factory settings (enabled if “dF Y” is selected)
Display test (tests for correct functioning of all LEDs)
Set T° offset
(Style 10-10S)
...
+
+
+
+
+
...
+
+
+
End of menu
+
+
+
Select mode: cod or loc (default cod)
Cod: the clock displays the time code data received, without modification.
Loc: the clock calculates and displays local time using the time code data received
plus its summer/winter time changeover and time difference settings.
+
Select
time zone
(default Eur)
+
+
+
+
+
+
+
+
S