Most of the cabling for the BTX6125HK is carried out at the factory. This guide only covers the cabling required on
installation. All cables to be attached are located around the sides of the BT6102E: 1 power supply with a green
connector (240V) and 1 communications cable with a green connector (DATA).
1/ Open all access covers.
2/ Connect a communications cable to the COM card on the BTX6025HK to the COM card of the
BTX6102HK (A).
3/ Connect a 240V power supply cable using the green connector on the BTX6025HK to the connector
on the BTX6102HK (B).
4/ Connect the 240V + earth mains cable to the power supply of the BTX6025HK (E) (power cable
(3x1.5²) not supplied by BODET).
2.4 DIPs settings
Card main panel
On the first DIP bank
On the 1st dip bank, dips 1 to 4 are used for the factory configuration of the panel.
Out of the factory the dips are set as follow:
Dip 1
Dip 2
Dip 3
Dip4
on ↑
on ↑
on ↑
on ↑
Dips 5 to 7 are used to identify each panel (If several panels are used on the same site each
panel must have its own number.).
Dip 8 is not used.
A
B
C
First DIP bank
Second DIP bank
Panel number
Dip 5
Dip 6
Dip 7
1
off ↓
on ↑
on ↑
2
on ↑
off ↓
on ↑
3
off ↓
off ↓
on ↑
4
on ↑
on ↑
off ↓
5
off ↓
on ↑
off ↓
6
on ↑
off ↓
off ↓