background image

7

3.  CoMMissioninG

Netsilon configuration is performed exclusively on the web server. In order to be able to access the web server it is 

necessary to configure the ETH0 port via the front panel keypad and the LCD screen. 

TIP:  in order not to disrupt Netsilon synchronisation with the other products present on the network, it is 

important to maintain identification of the time server.

 

 

There are two solutions for accessing the web server:

 

With a DHCP server: automatic assignment of an IP address.

 

>  

Without a DHCP server: 

manual assignment of a fixed IP address via the control panel in the Netsilon network 

menu.

3.1 

Factory configuration

The default configuration parameters have been selected to facilitate initial configuration. A single account is 

activated on shipment from the factory.

 

Default web server user account: 

  

Username: bodetadmin 

  

Password: admin49

 

 

 This account cannot be deleted. However, it is strongly recommended to change the password

When first running Netsilon, the default parameters are as follows:

Functions

Default status

Means of configuration

Control panel & LCD 

screen

Unlocked

Control panel (technician menu) + web server

Language: English 

Web Server

Rotation of information: time, 

network, synchronisation and 

system status

Web Server

USB port

Enabled

Web Server

ETH0 Ethernet port

DHCP: ON 

Control panel + web server

IP address not given

Control panel + web server

Services

DNS: ON (only)

HTTP: ON

Web Server 

(only HTTPS can be enabled or disabled)

Summary of Contents for 900 NETSILON 7

Page 1: ... report any concerns to the carrier BODET SA BP30001 49340 Trementines France Tel support France 02 41 71 72 99 Fax France 02 41 71 72 01 Ref 608072 A www bodet time com This document refers to the following products 907 900 NETSILON 7 100 240 VAC 907 901 NETSILON 7 18 36 VDC 907 902 NETSILON 7 100 240 VAC 18 36 VDC ...

Page 2: ...ning the equipment 5 2 2 3 Earth connection 5 2 3 Mechanical rack installation 6 2 4 Electrical installation 6 2 4 1 Power supply 6 2 4 2 Backup battery CR2032 6 2 4 3 Ethernet 6 2 4 4 Alarm relay circuits 6 3 Commissioning 7 3 1 Factory configuration 7 3 2 Choosing the LCD screen display language 8 3 3 Configuration with a DHCP server 8 3 4 Configuration without a DHCP server 9 4 WEB SERVER MENUS...

Page 3: ...l contains a USB1 1 port three status LEDs for power supply synchronisation and alarms Power Sync and Alarm 2 See Chapter 7 1 Status of LEDs on front panel page 57 a two line LCD display 3 control keys 4 for initial setup full setup from the web server 1 2 2 Rear panel Netsilon 7 100 240 VAC 18 36 VDC 1 Earth 2 On Off switch 3 Mains IEC 320 AC power inlets 4 18 36 VDC power supply terminal 3 81mm ...

Page 4: ...allation guide 6 Common Normally Closed Normally Open relay contact output If contact Normally Open no alarms If contact Normally Closed alarms 7 Terminal for GPS antenna 8 Alarms input interfaces with the dry contact of the client equipment 9 Serial port 10 ETH0 network card Netsilon 7 100 240 VAC Netsilon 7 18 36 VDC ...

Page 5: ...and maintenance of your product 2 2 1 Installing the equipment The installation and maintenance of this device must be performed by accredited personnel This product must not be installed by unauthorised users operators Electrical installation of the equipment must comply with applicable electrical standards 2 2 2 Opening the equipment There are no user repairable parts inside this equipment Pleas...

Page 6: ...C cable and observe the polarity indicated at the rear of the device 2 4 2 Backup battery CR2032 If replacing the CR2032 battery it is essential to observe the polarity as indicated on the slot of the battery There is a risk of explosion if the battery is replaced by a non compliant battery Dispose of used batteries in accordance with the instructions given on our website 2 4 3 Ethernet The ETH0 E...

Page 7: ...iguration The default configuration parameters have been selected to facilitate initial configuration A single account is activated on shipment from the factory Default web server user account Username bodetadmin Password admin49 This account cannot be deleted However it is strongly recommended to change the password When first running Netsilon the default parameters are as follows Functions Defau...

Page 8: ...ss on the LCD screen consult the network menu using the Netsilon control panel and LCD screen 3 Enter the IP address as seen on the LCD screen into the web browser Google Chrome Mozilla Firefox or Microsoft Internet Explorer 4 See Chapter 4 Web server menus page 15 N B 192 168 1 0 24 is the IP address with CIDR notation Exit the menu by pressing the button Lang uag e ok õ Lang uag e ok õ Language ...

Page 9: ...its used in the netmask may range from 8 to 30 bits Gateway The gateway address is required if communication with Netsilon is outside the local network By default the gateway is disabled To configure these three parameters use the Netsilon network menu via its control panel 10 54 32 Tues 19 SEP 2016 10 54 32 Tues 19 SEP 2016 System ok Network õ Network ok USB transfer õ Display ETH0 ok Config ETH0...

Page 10: ... the web server For info Username bodetadmin Password admin49 For more information download full manual SYSTEM General Online help 5 SUPPORT To request technical assistance for this equipment http www bodet time com assistance clientele html Telephone support is available from Monday to Friday from 8 am to 12 pm and from 1 30 pm to 5 pm To speed up the diagnosis of your Netsilon perform a system b...

Reviews: