background image

18

L

M

6

4

Step 7

After the mortar (M) has hardened, 
connect the sockets and mount the device 
carrier  in the housing � Then cut the 
recesses for the flexible cables (L) and for 
the cable glands  in the stones so that 
they can be laid flat on the floor socket 
without damaging the cables (see figure 
below and opposite view on the right)

Summary of Contents for 76 A-Series

Page 1: ...Bedienungsanleitung Instruction Manual 76er A Serie 76 A Series...

Page 2: ...2 Inhalt Contents Technische Daten 3 Produktbeschreibung 4 Montageanleitung 5 Gebrauchshinweise 21 Technical specifications 3 Product description 4 Assembly instructions 13 Instructions for use 21...

Page 3: ...IP67 IP67 Belastbarkeit Fl chenlast max 900kg Fl chenlast max 900kg Fl chenlast max 900kg Technische Daten Technical specifications Item No 7601A 7602A 7604A Instl dim 100x100x82mm 200x100x82mm 200x20...

Page 4: ...arts Kabelverschraubungen Cable glands 4 St ck Pieces Zubeh r Parts 76er A Serie 76 A Series Exemplarisch ist die Bodensteckdose 7602A abgebildet Das Montageprinzip gilt f r alle Bodensteckdosen der 7...

Page 5: ...den Ger tetr ger von dem Geh use abmontieren Anschlie end die Kabelverschraubungen anbringen Schritt 2 Vorbereitungen Vor dem Pflastern die Einbauposition f r die Bodensteckdose festlegen und die flex...

Page 6: ...enbelag B Pflastersteine bis zur Einbauposition der Bodensteckdose verlegen und die Bodensteckdose als Platzhalter einsetzen Alternativ einen Platzhalter aus Polystyrol in den Einbauma en der Bodenste...

Page 7: ...M K SP Schritt 4 Anschlie end die Plastersteinreihe zu Ende verlegen die Bodensteckdose den Platzhalter entnehmen und ein M rtelbett M an der Einbauposition auf den verdichteten Untergrund K z B Kies...

Page 8: ...8 L M SP 6 4 Schritt 5 Hiernach die flexiblen Leitungen L durch die Kabelverschraubungen in das Geh use einf hren und die Bodensteckdose in das M rtelbett M einsetzen...

Page 9: ...Die Position der Bodensteckdose vor dem Aush rten des M rtels M mit der Wasserwaage W berpr fen Achtung Die H he des M rtelbetts M muss so vermessen werden dass die Bodensteckdose und der Belag B b n...

Page 10: ...en Ger te tr ger in das Geh use montieren Danach Aussparungen f r die flexiblen Leitungen L und f r die Kabelverschrau bungen in die Steine schneiden siehe Abb unten und Gegenansicht rechts so dass di...

Page 11: ...11 Ansicht von der Gegenseite...

Page 12: ...12 Schritt 8 Mit dem Pflastern fortfahren Die Boden steckdose ist nun erfolgreich eingebaut...

Page 13: ...the lid and dismantle the device carrier from the housing Then attach the cable glands Step 2 Preparations Before paving determine the installation position for the floor socket and lay the flexible...

Page 14: ...overing B paving stones up to the installation position of the floor socket and use the floor socket as a place holder Alternatively cut a polystyrene placeholder in the size of the installation dimen...

Page 15: ...L B M K SP Step 4 Then lay the row of paving stones to the end remove the floor socket the place holder and pour a bed of mortar M at the installation position on the compacted subsurface K e g grave...

Page 16: ...16 L M SP 6 4 Step 5 Then insert the flexible cables L through the cable glands into the housing and insert the floor socket into the mortar bed M...

Page 17: ...6 Before the mortar M hardens check the position of the floor socket with the spirit level W Attention The height of the mortar bed M must be measured so that the floor socket and the covering B are f...

Page 18: ...ockets and mount the device carrier in the housing Then cut the recesses for the flexible cables L and for the cable glands in the stones so that they can be laid flat on the floor socket without dama...

Page 19: ...19 View from the opposite side...

Page 20: ...20 Step 8 Continue paving The floor socket is now successfully installed...

Page 21: ...technisch elektrisch darf das Produkt nicht in Betrieb genommen werden Das Produkt ist unter Beachtung der nationalen Vorschriften zu entsorgen Irrt mer und technische nderungen vorbehalten In order...

Page 22: ...n Subject to errors and technical changes by BS Bodensteckdosen Systemtechnik GmbH BS Bodensteckdosen Systemtechnik GmbH Dingerdisser Str 36 33699 Bielefeld Tel 49 5219892780 Fax 49 521989278 30 info...

Reviews: