5
The
BOCA SubATM printer
was designed to be mounted
within an unattended housing.
Prior to site preparation and installation, the printer should be powered up and run in the self-test
mode.
•
Lay the printer flat on a counter top.
•
Attach the AC cord and interface cable into the proper connectors.
•
Turn power on and you will hear the cutter motor cycle.
•
Begin loading tickets through the entrance slot with a smooth motion until the printer
automatically positions the ticket.
NOTE: Tickets should be loaded with the black mark facing down. Refer to the BOCA systems
website at
www.bocasystems.com
,
THERMAL TICKETS
section for
ticket specifications
.
•
After the ticket is automatically positioned, press the TEST button located on the electronics
box to print a test ticket.
•
Verify that the printer properly works with your system by issuing a ticket through your
computer system.
You may now install the printer in its permanent location. Adequate room should be provided behind
or underneath the printer for the smooth feeding of ticket stock.
5.0 Configuration
The
BOCA SubATM printer
is factory configured for a variety of customer requirements.
For a comparison of the different electronics packages, refer to the BOCA Systems website at
www.bocasystems.com
,
THE BASICS
section.
For a listing of configuration choices, refer to the BOCA Systems website at
www.bocasystems.com
,
SPECIFICATIONS
section.
Printers are configured with an adjustable paper guide set to the customer specified width. To
change the ticket width setting, refer to section 7.1.4.
Appendix A
shows a list of Control Panel functions. The SubATM printer is not supplied with a
Control Panel. In order to perform any Control Panel settings, a Control Panel must be connected to
the main logic board or commands must be downloaded through your software. Refer to the
programming guide
to perform settings through your software.
Click here to return to >
Table of Contents